Literature DB >> 19046825

Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance.

Jan-Jakob Sonke1, Maddalena Rossi, Jochem Wolthaus, Marcel van Herk, Eugene Damen, Jose Belderbos.   

Abstract

PURPOSE: To quantify the localization accuracy and intrafraction stability of lung cancer patients treated with frameless, four-dimensional (4D) cone beam computed tomography (CBCT)-guided stereotactic body radiotherapy (SBRT) and to calculate and validate planning target volume (PTV) margins to account for the residual geometric uncertainties.
MATERIALS AND METHODS: Sixty-five patients with small peripheral lung tumors were treated with SBRT without a body frame to 54 Gy in three fractions. For each fraction, three 4D-CBCT scans were acquired: before treatment to measure and correct the time-weighted mean tumor position, after correction to validate the correction applied, and after treatment to estimate the intrafraction stability. Patient-specific PTV margins were computed and subsequently validated using Monte Carlo error simulations.
RESULTS: Systematic tumor localization inaccuracies (1 SD) were 0.8, 0.8, and 0.9 mm for the left-right, craniocaudal, and anteroposterior direction, respectively. Random localization inaccuracies were 1.1, 1.1, and 1.4 mm. Baseline variations were 1.8, 2.9, and 3.0 mm (systematic) and 1.1, 1.5, and 2.0 mm (random), indicating the importance of image guidance. Intrafraction stability of the target was 1.2, 1.2, and 1.8 mm (systematic) and 1.3, 1.5, and 1.8 mm (random). Monte Carlo error simulations showed that patient-specific PTV margins (5.8-10.5 mm) were adequate for 94% of the evaluated cases (2-28 mm peak-to-peak breathing amplitude).
CONCLUSIONS: Frameless SBRT can be safely administered using 4D-CBCT guidance. Even with considerable breathing motion, the PTV margins can safely be kept small, allowing patients with larger tumors to benefit from the advantages of SBRT. In case bony anatomy would be used as a surrogate for tumor position, considerably larger PTV margins would be required.

Entities:  

Mesh:

Year:  2008        PMID: 19046825     DOI: 10.1016/j.ijrobp.2008.08.004

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  70 in total

1.  Positioning accuracy for lung stereotactic body radiotherapy patients determined by on-treatment cone-beam CT imaging.

Authors:  N D Richmond; K E Pilling; C Peedell; D Shakespeare; C P Walker
Journal:  Br J Radiol       Date:  2012-06       Impact factor: 3.039

2.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

Review 3.  Radiation dose effect in locally advanced non-small cell lung cancer.

Authors:  Feng-Ming Spring Kong; Jing Zhao; Jingbo Wang; Corrine Faivre-Finn
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

Review 4.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

5.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

6.  Evaluation of Elekta 4D cone beam CT-based automatic image registration for radiation treatment of lung cancer.

Authors:  Jun Li; Amy Harrison; Yan Yu; Ying Xiao; Maria Werner-Wasik; Bo Lu
Journal:  Br J Radiol       Date:  2015-07-17       Impact factor: 3.039

Review 7.  Are three doses of stereotactic ablative radiotherapy (SABR) more effective than 30 doses of conventional radiotherapy?

Authors:  Anna O Simeonova; Katharina Fleckenstein; Hansjörg Wertz; Anian Frauenfeld; Judit Boda-Heggemann; Frank Lohr; Frederik Wenz
Journal:  Transl Lung Cancer Res       Date:  2012-03

8.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

9.  A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer.

Authors:  J P Santoro; J McNamara; E Yorke; H Pham; A Rimner; K E Rosenzweig; G S Mageras
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

10.  Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control.

Authors:  Yali Shen; Hong Zhang; Jin Wang; Renming Zhong; Xiaoqing Jiang; Qinfeng Xu; Xin Wang; Sen Bai; Feng Xu
Journal:  Radiat Oncol       Date:  2010-02-27       Impact factor: 3.481

View more