Literature DB >> 19041630

Quantitative measurement of binding kinetics in sandwich assay using a fluorescence detection fiber-optic biosensor.

Chao-Hsiung Lin1, Hsaing-Yin Chen, Chih-Jen Yu, Pen-Li Lu, Chu-Hsin Hsieh, Bao-Yu Hsieh, Ying-Feng Chang, Chien Chou.   

Abstract

Fiber-optic biosensors have been studied intensively because they are very useful and important tools for monitoring biomolecular interactions. Here we describe a fluorescence detection fiber-optic biosensor (FD-FOB) using a sandwich assay to detect antibody-antigen interaction. In addition, the quantitative measurement of binding kinetics, including the association and dissociation rate constants for immunoglobulin G (IgG)/anti-mouse IgG, is achieved, indicating 0.38 x 10(6) M(-1) s(-1) for k(a) and 3.15 x 10(-3) s(-1) for k(d). These constants are calculated from the fluorescence signals detected on fiber surface only where the excited evanescent wave can be generated. Thus, a confined fluorescence-detecting region is achieved to specifically determine the binding kinetics at the vicinity of the interface between sensing materials and uncladded fiber surface. With this FD-FOB, the mathematical deduction and experimental verification of the binding kinetics in a sandwich immunoassay provide a theoretical basis for measuring rate constants and equilibrium dissociation constants. A further measurement to study the interaction between human heart-type fatty acid-binding protein and its antibody gave the calculated kinetic constants k(a), k(d), and K(D) as 8.48 x 10(5) M(-1) s(-1), 1.7 x 10(-3) s(-1), and 2.0 nM, respectively. Our study is the first attempt to establish a theoretical basis for the florescence-sensitive immunoassay using a sandwich format. Moreover, we demonstrate that the FD-FOB as a high-throughput biosensor can provide an alternative to the chip-based biosensors to study real-time biomolecular interaction.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19041630     DOI: 10.1016/j.ab.2008.11.010

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  4 in total

1.  Optical biosensors for food quality and safety assurance-a review.

Authors:  K Narsaiah; Shyam Narayan Jha; Rishi Bhardwaj; Rajiv Sharma; Ramesh Kumar
Journal:  J Food Sci Technol       Date:  2011-07-06       Impact factor: 2.701

2.  Long wavelength fluorescence lifetime standards for front-face fluorometry.

Authors:  Bryan J McCranor; Richard B Thompson
Journal:  J Fluoresc       Date:  2009-12-02       Impact factor: 2.217

Review 3.  Evaluation of optical detection platforms for multiplexed detection of proteins and the need for point-of-care biosensors for clinical use.

Authors:  Samantha Spindel; Kim E Sapsford
Journal:  Sensors (Basel)       Date:  2014-11-25       Impact factor: 3.576

Review 4.  Fluorescence based fiber optic and planar waveguide biosensors. A review.

Authors:  Elena Benito-Peña; Mayra Granda Valdés; Bettina Glahn-Martínez; Maria C Moreno-Bondi
Journal:  Anal Chim Acta       Date:  2016-09-13       Impact factor: 6.558

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.