Literature DB >> 19041480

Nonarteritic anterior ischemic optic neuropathy: refractive error and its relationship to cup/disc ratio.

Sohan Singh Hayreh1, M Bridget Zimmerman.   

Abstract

OBJECTIVE: To investigate refractive error in eyes with nonarteritic anterior ischemic optic neuropathy (NA-AION) and its relationship to cup/disc (C/D) ratio.
DESIGN: Cohort study. PARTICIPANTS: A total of 608 consecutive patients with NA-AION.
METHODS: At first visit, all patients had a comprehensive ophthalmic evaluation, including recording best-corrected visual acuity, visual fields, anterior segment examination, ophthalmoscopy, and fluorescein fundus angiography. Morphometric measurement of C/D ratio was performed in 65 fellow normal eyes in patients with unilateral NA-AION. Refraction was converted into spherical equivalent for data analysis. The data were analyzed using Pearson correlation, Mantel-Haenszel chi-square test, Cochran-Mantel-Haenszel test, chi-square goodness-of-fit test, and segmented linear regression. MAIN OUTCOME MEASURES: Refractive error in NA-AION eyes and any association between refractive error and C/D ratio.
RESULTS: Mean age of patients with NA-AION was 60.9 (standard deviation [SD] = 12.6; range 20.5-95.2) years. Median time from onset to refraction was 2 weeks (interquartile range 1-5 weeks). There was a significant association between spherical equivalent and age (P<0.0001). Comparison of refraction in patients with NA-AION who were aged >or=50 years with that of an age-matched general population in the Framingham study cohort showed no significant difference between the 2 groups (P = 0.289). Comparison with the age-matched US population from the 1999-2000 National Health and Nutrition Examination Survey showed a higher proportion of NA-AION eyes with spherical equivalent from -0.5 to 0.5 diopters and a smaller proportion with -3 to <-0.5 and >0.5 to +3 diopters (P<0.001). For horizontal C/D ratio, a higher degree of myopia and higher degree of hyperopia were significantly associated with a larger C/D ratio (P<0.021). A similar pattern was seen for vertical C/D ratio in hyperopia (P = 0.057) but not in myopia (P = 0.428).
CONCLUSIONS: There was a significant association between spherical equivalent refraction and age (P<0.0001). C/D ratio in persons with NA-AION is significantly smaller than that seen in the general population. Morphometric study in patients with NA-AION showed that a higher degree of myopia and higher degree of hyperopia are significantly associated with a larger C/D ratio. FINANCIAL DISCLOSURE(S): The authors have no proprietary or commercial interest in any materials discussed in this article.

Entities:  

Mesh:

Year:  2008        PMID: 19041480     DOI: 10.1016/j.ophtha.2008.08.007

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  15 in total

1.  Non-arteritic anterior ischemic optic neuropathy and thrombophilia.

Authors:  Sohan Singh Hayreh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

2.  Management of non-arteritic anterior ischemic optic neuropathy.

Authors:  Sohan Singh Hayreh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-12       Impact factor: 3.117

3.  An Experimental Animal Model of Photodynamic Optic Nerve Head Injury (PONHI).

Authors:  Dimosthenis Mantopoulos; Peggy Bouzika; Athanassios Tsakris; Basil S Pawlyk; Michael A Sandberg; Joan W Miller; Joseph F Rizzo Iii; Demetrios G Vavvas; Dean M Cestari
Journal:  Curr Eye Res       Date:  2016-05-09       Impact factor: 2.424

4.  Imageology of internal carotid artery siphon in non-arteritic anterior ischaemic optic neuropathy.

Authors:  Zhi-Yong Fu; Hong-Yang Li; Yan-Ling Wang
Journal:  Int J Ophthalmol       Date:  2020-12-18       Impact factor: 1.779

Review 5.  Perioperative Visual Loss in Cardiac Surgery.

Authors:  Jacob Raphael; Heather E Moss; Steven Roth
Journal:  J Cardiothorac Vasc Anesth       Date:  2018-11-24       Impact factor: 2.628

6.  Crowded optic nerve head evaluation with optical coherence tomography in anterior ischemic optic neuropathy.

Authors:  S Moghimi; M Afzali; M Akbari; K B Ebrahimi; A Khodabande; A R Yazdani-Abyaneh; S N H Ghafouri; P Coh; S Okhravi; M A Fard
Journal:  Eye (Lond)       Date:  2017-04-07       Impact factor: 3.775

7.  A new characterization for nonarteritic anterior ischemic optic neuropathy.

Authors:  Aipeng Li; Lin Li; Miyang Li; Xiaoru Shi
Journal:  Int J Clin Exp Med       Date:  2015-10-15

8.  Assessment of functional and morphometric endpoints in patients with non-arteritic anterior ischemic optic neuropathy (NAION).

Authors:  Christoph Kernstock; Flemming Beisse; Sarah Wiethoff; Andrea Mast; Elke Krapp; Regine Grund; Janko Dietzsch; Wolf Lagrèze; Dominik Fischer; Ulrich Schiefer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-01-31       Impact factor: 3.117

9.  Optic Nerve Head Elastometry in Both Eyes of Patients with Unilateral Non-arteritic Anterior Ischaemic Optic Neuropathy - May It Be a Novel Aspect of the Pathogenesis?

Authors:  Pinar Kosekahya; Mehtap Caglayan; Ozlem Unal; Sema Yuzbasioglu; Mustafa Koc; Cemile Ucgul Atilgan; Fatma Yulek
Journal:  Neuroophthalmology       Date:  2017-11-09

10.  Management of ischemic optic neuropathies.

Authors:  Sohan Singh Hayreh
Journal:  Indian J Ophthalmol       Date:  2011 Mar-Apr       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.