Tensioning of anterior cruciate ligament hamstring grafts: comparing equal tension versus equal stress.

Chad S Conner1, Randal P Morris, Santaram Vallurupalli, William L Buford, Frank M Ivey.   

Abstract

PURPOSE: A biomechanical study was undertaken to determine whether equal-stress or equal-tension tensioning of anterior cruciate ligament 4-stranded semitendinosus and gracilis grafts provides a stronger graft construct when testing to ultimate failure.
METHODS: Eighteen fresh-frozen cadaveric semitendinosus and gracilis tendons were each positioned over a cylinder rod/cryo-clamp connected to an MTS machine (MTS Systems, Eden Prairie, MN) by another cryo-clamp. In the equal-tension group the 4 strands were equally tensioned by weights. In the equal-stress group a tensioning device applied equal stress based on the cross-sectional areas of the tendons. The tendons were preconditioned with 10 cycles and then tested to failure. Graft creep during the preconditioning cycle was determined by MTS measurement of the change in clamp distance.
RESULTS: The maximum loads of 4-stranded semitendinosus and gracilis grafts tensioned by equal stress were found to be similar to those of the grafts tensioned by equal tension (2,803 +/- 431 N and 2,772 +/- 461 N, respectively). The loads at first failure were 2,640 +/- 468 N and 2,452 +/- 461 N, respectively (P = .17). The preconditioning cycles showed that the equal-stress group resisted graft creep significantly better (P = .0003).
CONCLUSIONS: The strength of the 4-stranded hamstring graft when equally tensioned or equally stressed was equivalent when tested to failure. After 10 preconditioning cycles, equal stress resisted graft creep significantly better. Equal-stress tensioning offers an alternative tensioning method for 4-stranded hamstring grafts. CLINICAL RELEVANCE: Equal-stress tensioning offers an alternative tensioning method for 4-stranded hamstring grafts.

Mesh:

Substances:

Year:  2008        PMID: 19038701     DOI: 10.1016/j.arthro.2008.07.006

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  2 in total

1.  Effect of femoral tunnel position on graft tension curves and knee stability in anatomic double-bundle anterior cruciate ligament reconstruction.

Authors:  Hideyuki Koga; Takeshi Muneta; Kazuyoshi Yagishita; Toshifumi Watanabe; Tomoyuki Mochizuki; Masafumi Horie; Tomomasa Nakamura; Ichiro Sekiya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-24       Impact factor: 4.342

2.  The impact of tensioning device mal-positioning on strand tension during anterior cruciate ligament reconstruction.

Authors:  Rajesh Maharjan; John J Costi; Richard M Stanley; David Martin; Trevor C Hearn; John R Field
Journal:  J Orthop Surg Res       Date:  2011-06-28       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.