Comparison of bioabsorbable versus metallic implant fixation for physeal and epiphyseal fractures of the distal tibia.

David A Podeszwa1, Philip L Wilson, Amy R Holland, Lawson A B Copley.   

Abstract

BACKGROUND: Transepiphyseal screw fixation of displaced distal tibial epiphyseal fractures is the most common method of treatment for these intraarticular injuries. Recent literature indicates that retained transepiphyseal metallic screws cause an increase in ankle joint contact pressure, thus favoring screw removal. Our hypothesis is that bioabsorbable screw fixation is an alternative to metallic fixation, which offers similar results without the need for screw removal.
METHODS: This is a retrospective review of distal tibial epiphyseal ankle fractures treated with screw fixation. Two groups, those treated with bioabsorbable screw fixation (group B, n = 24) and those with metallic screw fixation (group M, n = 26), were compared (t test) for differences in clinical and radiographic outcomes.
RESULTS: Analysis of demographic data revealed no significant differences between groups for sex, ethnicity, age, and height. Group B was significantly heavier than group M (67.4 vs 55.6 kg; P = 0.0496). Each group had a similar number of Salter-Harris types III and IV medial malleolus fractures and transitional fracture types. There was no significant difference between groups in the time from injury to fixation or in operative time. Radiographically, there were no nonunions in either group, and at final follow-up, 1 patient in group B had distal tibial joint line irregularity versus 3 in group M. Clinically, there were no significant differences between groups in time to full weight bearing or time to full activities.There were fewer complications in group B. A single case of loss of reduction requiring revision fixation occurred in each group. There was one documented growth arrest in group M and 2 suspected growth arrests in each group. Two patients in group M were successfully treated for a superficial wound infection with oral antibiotics. Fourteen patients in group M underwent planned screw removal.
CONCLUSIONS: Bioabsorbable screw fixation can be used for distal tibial epiphyseal fractures with no increase in operative time, nonunion rate, number of unplanned secondary surgeries, or other complications. The use of bioabsorbable screws eliminates the need for epiphyseal screw removal. A prospective randomized study is planned to eliminate the potential selection bias and to standardize clinical and radiographic follow-up. LEVEL OF EVIDENCE: Level III, case-control study.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19034179     DOI: 10.1097/BPO.0b013e31818e19d7

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  6 in total

1.  Removal of orthopaedic implants: indications, outcome and economic implications.

Authors:  I I Onche; O E Osagie; S INuhu
Journal:  J West Afr Coll Surg       Date:  2011-01

2.  Treatment of distal tibial shaft fractures by three different surgical methods: a randomized, prospective study.

Authors:  Yongchuan Li; Xi Jiang; Qinghe Guo; Lei Zhu; Tianwen Ye; Aimin Chen
Journal:  Int Orthop       Date:  2014-02-19       Impact factor: 3.075

Review 3.  Pediatric Ankle Fractures: Concepts and Treatment Principles.

Authors:  Alvin W Su; A Noelle Larson
Journal:  Foot Ankle Clin       Date:  2015-10-16       Impact factor: 1.653

4.  Percutaneous cannulated screw fixation for pediatric epiphyseal ankle fractures.

Authors:  Özgür Çiçekli; Güzelali Özdemir; Mustafa Uysal; Vedat Biçici; İzzet Bingöl
Journal:  Springerplus       Date:  2016-11-07

5.  Cannulated screw and Kirschner fixation for the treatment of medial and lateral malleolar epiphyseal fractures in children: a retrospective study of 36 cases.

Authors:  Linjun Jiang; Jun Wu; Ming Li; Xing Liu; Cong Luo; Xiangyang Qu
Journal:  J Orthop Surg Res       Date:  2019-08-08       Impact factor: 2.359

6.  Lateral condyle fracture of the humerus in children treated with bioabsorbable materials.

Authors:  Véronique Andrey; Stéphane Tercier; Frédéric Vauclair; Aline Bregou-Bourgeois; Nicolas Lutz; Pierre-Yves Zambelli
Journal:  ScientificWorldJournal       Date:  2013-10-09
  6 in total