Literature DB >> 19027326

An assessment of the reliability and standardisation of tests used to elicit reference muscular actions for electromyographical normalisation.

N Ball1, J Scurr.   

Abstract

Prior to implementing a normalisation method, the standardisation and reliability of the method needs to be examined. This investigation aimed to assess the reliability of EMG amplitudes and test outputs from proposed normalisation methods for the triceps surae. Sixteen participants completed isometric (maximum and sub-maximum); isokinetic (1.05rad/s, 1.31rad/s and 1.83rad/s) squat jump and 20m sprint conditions, on 3 separate occasions over 1week. The EMG data was collected from the medial and lateral gastrocnemius (MG and LG) and soleus (SOL). Log transformed typical error measurements (TEM(CV%)) assessed EMG signal and test output reliability across the three sessions. Only the squat jump provided acceptable EMG reliability for all muscles both between days (SOL: 13%; MG: 14.5%; LG: 11.8%) and between weeks (SOL: 14.5%; MG: 12.9%; LG: 8.9%), with the sprint only showing poor reliability in the LG between days (16.3%). Acceptable reliability for the isometric and isokinetic conditions were muscle and re-test period dependant. Reliable output was found for the squat jump (4.1% and 3.6%), sprint (0.8% and 0.6%) and 1RM plantar flexion test (2.8% and 3.5%) between days and weeks, respectively. Isokinetic plantar flexion displayed poor reliability at all velocities between days and weeks. It was concluded that the squat jump provides a standardised and reproducible reference EMG value for the triceps surae for use as a normalisation method.

Entities:  

Mesh:

Year:  2010        PMID: 19027326     DOI: 10.1016/j.jelekin.2008.09.004

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  10 in total

1.  Textile Electrodes Embedded in Clothing: A Practical Alternative to Traditional Surface Electromyography when Assessing Muscle Excitation during Functional Movements.

Authors:  Steffi L Colyer; Polly M McGuigan
Journal:  J Sports Sci Med       Date:  2018-03-01       Impact factor: 2.988

2.  Muscle activation during maximum voluntary contraction and m-wave related in healthy but not in injured conditions: Implications when normalizing electromyography.

Authors:  Jennifer A Zellers; Sheridan Parker; Adam Marmon; Karin Grävare Silbernagel
Journal:  Clin Biomech (Bristol, Avon)       Date:  2019-07-05       Impact factor: 2.063

3.  Can Kinesio Taping® influence the electromyographic signal intensity of trunk extensor muscles in patients with chronic low back pain? A randomized controlled trial.

Authors:  Leandro Garcia Pires; Rosimeire Simprini Padula; Maurício Antônio Da Luz Junior; Irlei Santos; Matheus Oliveira Almeida; Shaiane Silva Tomazoni; Lucíola Cunha Menezes Costa; Leonardo Oliveira Pena Costa
Journal:  Braz J Phys Ther       Date:  2019-12-15       Impact factor: 3.377

4.  Reliability of isometric subtalar pronator and supinator strength testing.

Authors:  Marco Hagen; Matthias Lahner; Martin Winhuysen; Christian Maiwald
Journal:  J Foot Ankle Res       Date:  2015-04-17       Impact factor: 2.303

5.  Reliability of quadriceps surface electromyography measurements is improved by two vs. single site recordings.

Authors:  T G Balshaw; A Fry; T M Maden-Wilkinson; P W Kong; J P Folland
Journal:  Eur J Appl Physiol       Date:  2017-04-08       Impact factor: 3.078

6.  Surface Electromyographic Analysis of the Suprahyoid Muscles in Infants Based on Lingual Frenulum Attachment during Breastfeeding.

Authors:  Ellia Christinne Lima França; Lucas Carvalho Aragão Albuquerque; Roberta Lopes Castro Martinelli; Ilda Machado Fiuza Gonçalves; Cejana Baiocchi Souza; Maria Alves Barbosa
Journal:  Int J Environ Res Public Health       Date:  2020-01-30       Impact factor: 3.390

7.  Effects of hyperoxia on dynamic muscular endurance are associated with individual whole-body endurance capacity.

Authors:  Yuta Kojima; Chiho Fukusaki; Naokata Ishii
Journal:  PLoS One       Date:  2020-04-21       Impact factor: 3.240

8.  Reliability of Electromyographic Assessment of Biceps Brachii and Triceps Brachii in Cricketers.

Authors:  Deepika Singla; Mohammad Ejaz Hussain; Pooja Bhati; Jamal Ali Moiz; Irshad Ahmad; Shalini Verma; Kamran Ali
Journal:  J Chiropr Med       Date:  2018-08-28

9.  Electromyographic analysis of masseter muscle in newborns during suction in breast, bottle or cup feeding.

Authors:  Ellia C L França; Cejana B Sousa; Lucas C Aragão; Luciane R Costa
Journal:  BMC Pregnancy Childbirth       Date:  2014-05-01       Impact factor: 3.007

10.  Comparison of maximum voluntary isometric contraction of the biceps on various posture and respiration conditions for normalization of electromyography data.

Authors:  Sang-Yeol Lee; Marg-Eun Jo
Journal:  J Phys Ther Sci       Date:  2016-11-29
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.