Literature DB >> 19021985

Surgery for marfan patients with acute type a dissection using a stented elephant trunk procedure.

Lizhong Sun1, Ruidong Qi, Qian Chang, Junming Zhu, Yongmin Liu, Chuntao Yu, Haitao Zhang, Bin Lv, Jun Zheng, Liangxin Tian, Jinguo Lu.   

Abstract

BACKGROUND: The purpose of the study was to assess the efficacy of total arch replacement combined with stented elephant trunk implantation for Marfan patients with acute Stanford type A aortic dissection involving the aortic arch.
METHODS: Between January 2004 and April 2006, 13 consecutive Marfan patients (4 female, 9 male) with acute type A aortic dissection involving the aortic arch underwent total arch replacement combined with implantation of a stented elephant trunk. Aortic dissection extending to the iliac artery was seen in 10 patients, and to the abdominal aorta in 3 patients. Ages ranged from 17 to 65 years (mean, 39 +/- 13). Computed tomography was done to evaluate the residual false lumen in the descending aorta.
RESULTS: All patients survived and were discharged from hospital. One patient with thrombosis of the innominate artery suffered cerebral infarction and recovered during follow-up. One patient had ischemia of the left upper limb postoperatively, but recovered after axillary to axillary artery bypass. There was 1 death during the mean follow-up period of 27 +/- 10 months. Complete thrombus formation was observed in 84.6% of patients (11 of 13) around the stented elephant trunk, and in 69.2% of patients (9 of 13) at the diaphragmatic level.
CONCLUSIONS: Total arch replacement combined with stented elephant trunk implantation for Marfan patients with acute type A aortic dissection involving the aortic arch results in less late dilatation of the dissected descending aorta. That prolongs the reoperation interval or reduces the number of late thoracoabdominal aortic replacements, unless there is a patent false lumen around the stented elephant trunk.

Entities:  

Mesh:

Year:  2008        PMID: 19021985     DOI: 10.1016/j.athoracsur.2008.08.026

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  Dr. Sun's Procedure for Type A Aortic Dissection: Total Arch Replacement Using Tetrafurcate Graft With Stented Elephant Trunk Implantation.

Authors:  Wei-Guo Ma; Jun Zheng; Yong-Min Liu; Jun-Ming Zhu; Li-Zhong Sun
Journal:  Aorta (Stamford)       Date:  2013-06-01

2.  Decision-making at initial surgery for type A aortic dissection in patients with Marfan syndrome: proximal or extensive repair.

Authors:  Ning Li; Yu Zhang; Yuan Gao; Yifan Bai; Zhao An; Guanxin Zhang; Qingqi Han; Fanglin Lu; BaiLing Li; Lin Han; Zhiyun Xu
Journal:  J Thorac Dis       Date:  2019-12       Impact factor: 2.895

3.  Total arch replacement and frozen elephant trunk for type A aortic dissection after Bentall procedure in Marfan syndrome.

Authors:  Yu Chen; Wei-Guo Ma; Jun Zheng; Yong-Min Liu; Jun-Ming Zhu; Li-Zhong Sun
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

4.  Is the frozen elephant trunk technique justified for chronic type A aortic dissection in Marfan syndrome?

Authors:  Yu Chen; Wei-Guo Ma; Jian-Rong Li; Jun Zheng; Yong-Min Liu; Jun-Ming Zhu; Li-Zhong Sun
Journal:  Ann Cardiothorac Surg       Date:  2020-05

5.  Long-term outcomes after aortic root replacement for patients with Marfan syndrome.

Authors:  Yu Zhu; Zhao Jian; Ruiyan Ma; Yong Wang; Yingbin Xiao
Journal:  J Thorac Dis       Date:  2021-12       Impact factor: 2.895

6.  Surgical approach for the treatment of aortoesophageal fistula combined with dual aortic aneurysms: a case report.

Authors:  Rihao Xu; Tiance Wang; Dan Li; Zhicheng Zhu; Shudong Zhang; Chengluan Xuan; Wen Yan; Kexiang Liu
Journal:  J Cardiothorac Surg       Date:  2013-11-04       Impact factor: 1.637

Review 7.  Surgical repair and reconstruction of aortic arch in debakey type I aortic dissection: recent advances and single-center experience in the application of branched stent graft.

Authors:  Qian Zhang; Xiaochun Ma; Wenlong Zhang; Zhengjun Wang; Haizhou Zhang; Xiaofeng Zhang; Jian Song; Chengwei Zou
Journal:  J Cardiothorac Surg       Date:  2017-10-03       Impact factor: 1.637

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.