Literature DB >> 19021414

Topographical variations in the polarization sensitivity of articular cartilage as determined by polarization-sensitive optical coherence tomography and polarized light microscopy.

Tuqiang Xie1, Yang Xia, Shuguang Guo, Patrick Hoover, Zhongping Chen, George M Peavy.   

Abstract

To understand the influence of topographical variations in collagen fibril orientation of articular cartilage on optical phase images of polarization-sensitive optical coherence tomography (PS-OCT), we use polarized light microscopy (PLM) to quantify the orientation and phase retardation of the collagen architecture in cartilage at the same locations imaged by PS-OCT. The PS-OCT experiments demonstrate that articular cartilage has normal variations in polarization sensitivity at different locations over an intact bovine tibial plateau. Articular cartilage is not polarization sensitive along the vertical axis on the medial edge and central areas of the joint surface, but becomes polarization sensitive on the lateral edge of the tibia. This difference in optical phase retardation, as demonstrated by PS-OCT, is verified by PLM to be caused by differences in collagen fibril orientation at different locations of the tibial plateau. This study demonstrates that normal topographical variations in the collagen architecture of articular cartilage within a joint have a profound influence on the optical phase retardation detected by PS-OCT imaging, and therefore must be understood and mapped for specific joints before PS-OCT imaging can be used for the evaluation of the health status of individual joint surfaces.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19021414      PMCID: PMC2866638          DOI: 10.1117/1.2976422

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  31 in total

1.  In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography.

Authors:  B H Park; C Saxer; S M Srinivas; J S Nelson; J F de Boer
Journal:  J Biomed Opt       Date:  2001-10       Impact factor: 3.170

2.  Characteristics of topographical heterogeneity of articular cartilage over the joint surface of a humeral head.

Authors:  Y Xia; J B Moody; H Alhadlaq; N Burton-Wurster; G Lust
Journal:  Osteoarthritis Cartilage       Date:  2002-05       Impact factor: 6.576

3.  The organisation of collagen fibrils in the superficial zones of articular cartilage.

Authors:  J M Clark
Journal:  J Anat       Date:  1990-08       Impact factor: 2.610

Review 4.  Optical coherence tomography.

Authors:  A Gh Podoleanu
Journal:  Br J Radiol       Date:  2005-11       Impact factor: 3.039

5.  Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation.

Authors:  Shuliang Jiao; Milos Todorović; George Stoica; Lihong V Wang
Journal:  Appl Opt       Date:  2005-09-10       Impact factor: 1.980

6.  Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT).

Authors:  Susanne D Giattina; Brian K Courtney; Paul R Herz; Michelle Harman; Sonya Shortkroff; Debra L Stamper; Bin Liu; James G Fujimoto; Mark E Brezinski
Journal:  Int J Cardiol       Date:  2006-01-23       Impact factor: 4.164

7.  High resolution imaging of normal and osteoarthritic cartilage with optical coherence tomography.

Authors:  J M Herrmann; C Pitris; B E Bouma; S A Boppart; C A Jesser; D L Stamper; J G Fujimoto; M E Brezinski
Journal:  J Rheumatol       Date:  1999-03       Impact factor: 4.666

8.  Arthroscopic microscopy of articular cartilage using optical coherence tomography.

Authors:  Constance R Chu; Diana Lin; Jessica L Geisler; Charleen T Chu; Freddie H Fu; Yingtian Pan
Journal:  Am J Sports Med       Date:  2004 Apr-May       Impact factor: 6.202

9.  High-resolution imaging of progressive articular cartilage degeneration.

Authors:  Samuel B Adams; Paul R Herz; Debra L Stamper; Mark J Roberts; Stephane Bourquin; Nirlep A Patel; Karl Schneider; Scott D Martin; Sonya Shortkroff; James G Fujimoto; Mark E Brezinski
Journal:  J Orthop Res       Date:  2006-04       Impact factor: 3.494

10.  Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

Authors:  Erich Götzinger; Michael Pircher; Markus Sticker; Adolf F Fercher; Christoph K Hitzenberger
Journal:  J Biomed Opt       Date:  2004 Jan-Feb       Impact factor: 3.170

View more
  7 in total

1.  Fourier-transform infrared spectroscopic imaging of articular cartilage and biomaterials: A review.

Authors:  Nagarajan Ramakrishnan; Yang Xia
Journal:  Trends Appl Spectrosc       Date:  2013

Review 2.  The role of interstitial fluid pressurization in articular cartilage lubrication.

Authors:  Gerard A Ateshian
Journal:  J Biomech       Date:  2009-05-22       Impact factor: 2.712

3.  Terahertz pulsed imaging of knee cartilage.

Authors:  Wai-Chi Kan; Win-Sze Lee; Wing-Hoi Cheung; Vincent P Wallace; Emma Pickwell-Macpherson
Journal:  Biomed Opt Express       Date:  2010-09-20       Impact factor: 3.732

4.  Arthroscopic optical coherence tomography in diagnosis of early arthritis.

Authors:  Michael J O'Malley; Constance R Chu
Journal:  Minim Invasive Surg       Date:  2011-04-03

5.  Comparison of optical coherence tomography and histopathology in quantitative assessment of goat talus articular cartilage.

Authors:  Paul Cernohorsky; Aimee C Kok; Daniel Martijn de Bruin; Martin J Brandt; Dirk J Faber; Gabrielle J Tuijthof; Gino M Kerkhoffs; Simon D Strackee; Ton G van Leeuwen
Journal:  Acta Orthop       Date:  2014-10-28       Impact factor: 3.717

6.  Quantifying birefringence in the bovine model of early osteoarthritis using polarisation-sensitive optical coherence tomography and mechanical indentation.

Authors:  Matthew Goodwin; Bastian Bräuer; Stephen Lewis; Ashvin Thambyah; Frédérique Vanholsbeeck
Journal:  Sci Rep       Date:  2018-06-05       Impact factor: 4.379

7.  Slope-based segmentation of articular cartilage using polarization-sensitive optical coherence tomography phase retardation image.

Authors:  Xin Zhou; Myeong Jin Ju; Lin Huang; Shuo Tang
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.