Validation of A&D UA-85X device for blood pressure measurement.

Elisa Bonso1, Fabio Ragazzo, Paolo Palatini.   

Abstract

To determine the accuracy of the UA-85X (UA-851, 852, 853, 854, and 855) device developed by the A&amp;D company. Device evaluations were performed using the protocol of the European Society of Hypertension (ESH). Monitor performance was assessed in relation to patients' age, arm circumference, and systolic and diastolic blood pressures (BPs). The device was assessed in two different samples according to ESH requirements, which are based on four zones of accuracy differing from the mercury standard by 5, 10, 15 mmHg, or more. The UA-85X passed all three phases of the protocol for systolic BP and diastolic BP. Mean BP difference between device and observers was -0.3+/-4.4 mmHg for systolic BP and -2.7+/-4.8 mmHg for diastolic BP. These passed the Association for the Advancement of Medical Instrumentation standard requirements. In multivariable analyses, systolic BP discrepancies between device and observers were related to age (P=0.03) and diastolic BP discrepancies were related to diastolic BP level (P<0.001). These data show that the UA-85X satisfies the recommended ESH and Advancement of Medical Instrumentation accuracy levels for both systolic BP and diastolic BP.

Entities:  

Mesh:

Year:  2008        PMID: 19020424     DOI: 10.1097/MBP.0b013e32830d4b77

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  4 in total

1.  Influence of blood pressure level and age on within-visit blood pressure variability in children and adolescents.

Authors:  Panagiota Veloudi; Christopher L Blizzard; Velandai K Srikanth; Martin G Schultz; James E Sharman
Journal:  Eur J Pediatr       Date:  2017-12-04       Impact factor: 3.183

2.  Age-Specific Associations of Usual Blood Pressure Variability With Cardiovascular Disease and Mortality: 10-Year Diabetes Mellitus Cohort Study.

Authors:  Eric Yuk Fai Wan; Esther Yee Tak Yu; Weng Yee Chin; Jessica K Barrett; Ian Chi Kei Wong; Esther Wai Yin Chan; Celine Sze Ling Chui; Shiqi Chen; Cindy Lo Kuen Lam
Journal:  J Am Heart Assoc       Date:  2021-08-16       Impact factor: 5.501

3.  Ambulatory blood pressure monitoring in patients with chronic kidney disease and resistant hypertension.

Authors:  Salman Shafi; Erdal Sarac; Huy Tran
Journal:  J Clin Hypertens (Greenwich)       Date:  2012-06-20       Impact factor: 3.738

4.  Discrepancy between tonometric ambulatory and cuff-based office blood pressure measurements in patients with type 1 diabetes.

Authors:  Simone Theilade; Maria Lajer; Christel Joergensen; Frederik Persson; Peter Rossing
Journal:  J Clin Hypertens (Greenwich)       Date:  2012-08-03       Impact factor: 3.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.