Literature DB >> 19020212

Microscopy coil for preoperative MRI of small soft-tissue masses of the hand and foot: comparison with conventional surface coil.

In Sook Lee1, Jung-Ah Choi, Joo Han Oh, Jin-Haeng Chung, Hee Sun Jeong, Sung Hwan Hong, Heung Sik Kang.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the usefulness of MRI performed with a microscopy coil in the preoperative evaluation of small soft-tissue masses of the hand and foot.
MATERIALS AND METHODS: Sixteen patients with clinically suspected soft-tissue masses of the hand or foot underwent MRI with both a conventional surface coil and a microscopy coil and were included in this study. All MR images were obtained with a 1.5-T system and a 47-mm microscopy coil. MR images were qualitatively analyzed for size, number, location, morphologic details, extent and margin quality, and growth pattern of the mass and the relation between the mass and adjacent anatomic structures. For quantitative analysis, we measured the signal-to-noise ratio of each mass on MR images obtained with both coils. MRI findings with the two coils were compared, and the findings were correlated with the surgical and histopathologic findings on all 16 patients who underwent surgery.
RESULTS: Relation between adjacent anatomic structures and the mass (n = 15), internal morphologic features (n = 14), and extent or margin quality (n = 11) of masses were clearly delineated on MRI performed with a microscopy coil (p = 0.0001). These findings correlated well with the surgical and pathologic findings. In addition, small soft-tissue masses not detected with a conventional surface coil were readily detected with a microscopy coil (n = 3). The signal-to-noise ratios of masses detected with a microscopy coil were significantly higher than those of masses detected with a conventional surface coil (p = 0.006).
CONCLUSION: MRI with a microscopy coil was useful in the preoperative assessment of small soft-tissue masses of the hand and foot.

Entities:  

Mesh:

Year:  2008        PMID: 19020212     DOI: 10.2214/AJR.07.3011

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  Accuracy of preoperative MRI with microscopy coil in evaluation of primary tumor thickness of malignant melanoma of the skin with histopathologic correlation.

Authors:  Yusuhn Kang; Jung-Ah Choi; Jin-Haeng Chung; Sung Hwan Hong; Heung Sik Kang
Journal:  Korean J Radiol       Date:  2013-02-22       Impact factor: 3.500

2.  Malignant peripheral nerve sheath tumor of the distal phalanx of the fifth toe: a case report.

Authors:  Yuki Iwama; Makoto Kunisada; Hajimu Goto; Yoshiharu Ohno; Junji Yamashita; Yoko Funasaka; Chikako Nishigori; Masahiko Fujii
Journal:  Acta Radiol Short Rep       Date:  2014-01-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.