Literature DB >> 19017344

Clinical experience with a single catheter for mapping and ablation of pulmonary vein ostium.

Paolo De Filippo1, Ding Sheng He, Roberta Brambilla, Antonello Gavazzi, Francesco Cantù.   

Abstract

INTRODUCTION: The aim of this single center study is to evaluate the safety and the efficacy of performing pulmonary vein isolation (PVI) using a single high-density mesh ablator (HDMA) catheter.
METHODS: A total of 17 consecutive patients with paroxysmal (10 patients) or persistent atrial fibrillation (7 patients) and no heart disease were enrolled. A single transseptal puncture was performed and the HDMA was placed at each PV ostium identified with anatomic and electrophysiological mapping. Pulsed radiofrequency (RF) energy was delivered at the targeted temperature of 58 degrees C with maximum power of 80 watts. No other ablation system was utilized. The primary objective of the study was acute isolation of the targeted PV, and the secondary objective was clinical efficacy and safety of PVI with HDMA for atrial fibrillation (AF) prevention. Patients were followed at intervals of 1, 3, 6, and 12 months.
RESULTS: PVI was attempted with HDMA in 67/67 PVs. [Correction made after online publication October 27, 2008: PVs changed from 6/67 to 67/67] Acute success rate were: 100% (16/16) for left superior PV, 100% (16/16) for left inferior PV, 100% (17/17) for right superior PV, 100% (1/1) for left common trunk and 47% (8/17) for right inferior PV. Total procedure time was 200 +/- 36 minutes (range 130-240 minutes) and total fluoroscopy time was 42 +/- 18 minutes (range 23-75 minutes). During a mean follow-up of 11 +/- 4 months, 64% of patients remained in sinus rhythm (8/10 paroxysmal AF and 3/7 for persistent AF). No complications occurred either acutely or at follow-up.
CONCLUSIONS: PV isolation with HDMA is feasible and safe. The midterm efficacy in maintaining sinus rhythm is higher in paroxysmal than in persistent patients.

Entities:  

Mesh:

Year:  2008        PMID: 19017344     DOI: 10.1111/j.1540-8167.2008.01340.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  8 in total

Review 1.  State-of-the-art and emerging technologies for atrial fibrillation ablation.

Authors:  Jane Dewire; Hugh Calkins
Journal:  Nat Rev Cardiol       Date:  2010-03       Impact factor: 32.419

2.  Electronic sensor and actuator webs for large-area complex geometry cardiac mapping and therapy.

Authors:  Dae-Hyeong Kim; Roozbeh Ghaffari; Nanshu Lu; Shuodao Wang; Stephen P Lee; Hohyun Keum; Robert D'Angelo; Lauren Klinker; Yewang Su; Chaofeng Lu; Yun-Soung Kim; Abid Ameen; Yuhang Li; Yihui Zhang; Bassel de Graff; Yung-Yu Hsu; Zhuangjian Liu; Jeremy Ruskin; Lizhi Xu; Chi Lu; Fiorenzo G Omenetto; Yonggang Huang; Moussa Mansour; Marvin J Slepian; John A Rogers
Journal:  Proc Natl Acad Sci U S A       Date:  2012-11-12       Impact factor: 11.205

Review 3.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  J Interv Card Electrophysiol       Date:  2012-03       Impact factor: 1.900

4.  Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation.

Authors:  Giuseppe Stabile; Matteo Anselmino; Ezio Soldati; Ermengildo De Ruvo; Francesco Solimene; Assunta Iuliano; Luigi Sciarra; Maria Grazia Bongiorni; Leonardo Calò; Fiorenzo Gaita
Journal:  J Interv Card Electrophysiol       Date:  2016-10-06       Impact factor: 1.900

5.  Eighteen months follow-up of the clinical efficacy of the high density mesh ablator (HDMA) in patients with atrial fibrillation after pulmonary vein isolation.

Authors:  Petra Maagh; Marc van Bracht; Thomas Butz; Hans-Joachim Trappe; Axel Meissner
Journal:  J Interv Card Electrophysiol       Date:  2010-07-16       Impact factor: 1.900

6.  Safety of atrial fibrillation ablation with novel multi-electrode array catheters on uninterrupted anticoagulation-a single-center experience.

Authors:  Christopher Ruslan Hayes; David Keane
Journal:  J Interv Card Electrophysiol       Date:  2010-03       Impact factor: 1.900

Review 7.  [Pulmonary vein isolation with multipolar ablation catheters for the treatment of paroxysmal atrial fibrillation].

Authors:  H Bauerle; T Japha; B-D Gonska
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-06

8.  Pulmonary vein potential mapping in atrial fibrillation with high density and standard spiral (lasso) catheters: A comparative study.

Authors:  Axel Meissner; Petra Maagh; Arnd Christoph; Ahmet Oernek; Gunnar Plehn
Journal:  J Arrhythm       Date:  2016-11-25
  8 in total