Literature DB >> 19015523

Multitarget magnetic activated cell sorter.

Jonathan D Adams1, Unyoung Kim, H Tom Soh.   

Abstract

Magnetic selection allows high-throughput sorting of target cells based on surface markers, and it is extensively used in biotechnology for a wide range of applications from in vitro diagnostics to cell-based therapies. However, existing methods can only perform separation based on a single parameter (i.e., the presence or absence of magnetization), and therefore, the simultaneous sorting of multiple targets at high levels of purity, recovery, and throughput remains a challenge. In this work, we present an alternative system, the multitarget magnetic activated cell sorter (MT-MACS), which makes use of microfluidics technology to achieve simultaneous spatially-addressable sorting of multiple target cell types in a continuous-flow manner. We used the MT-MACS device to purify 2 types of target cells, which had been labeled via target-specific affinity reagents with 2 different magnetic tags with distinct saturation magnetization and size. The device was engineered so that the combined effects of the hydrodynamic force produced from the laminar flow and the magnetophoretic force produced from patterned ferromagnetic structures within the microchannel result in the selective purification of the differentially labeled target cells into multiple independent outlets. We demonstrate here the capability to simultaneously sort multiple magnetic tags with >90% purity and >5,000-fold enrichment and multiple bacterial cell types with >90% purity and >500-fold enrichment at a throughput of 10(9) cells per hour.

Entities:  

Mesh:

Year:  2008        PMID: 19015523      PMCID: PMC2587622          DOI: 10.1073/pnas.0809795105

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  21 in total

Review 1.  Use of magnetic techniques for the isolation of cells.

Authors:  I Safarík; M Safaríková
Journal:  J Chromatogr B Biomed Sci Appl       Date:  1999-02-05

2.  Pinched flow fractionation: continuous size separation of particles utilizing a laminar flow profile in a pinched microchannel.

Authors:  Masumi Yamada; Megumi Nakashima; Minoru Seki
Journal:  Anal Chem       Date:  2004-09-15       Impact factor: 6.986

3.  Blue fluorescent proteins with enhanced brightness and photostability from a structurally targeted library.

Authors:  Marco A Mena; Thomas P Treynor; Stephen L Mayo; Patrick S Daugherty
Journal:  Nat Biotechnol       Date:  2006-11-19       Impact factor: 54.908

4.  On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates.

Authors:  Nicole Pamme; Andreas Manz
Journal:  Anal Chem       Date:  2004-12-15       Impact factor: 6.986

5.  High gradient magnetic cell separation with MACS.

Authors:  S Miltenyi; W Müller; W Weichel; A Radbruch
Journal:  Cytometry       Date:  1990

6.  Traveling wave magnetophoresis for high resolution chip based separations.

Authors:  Benjamin B Yellen; Randall M Erb; Hui S Son; Rodward Hewlin; Hao Shang; Gil U Lee
Journal:  Lab Chip       Date:  2007-10-17       Impact factor: 6.799

7.  Microfluidic device architecture for electrochemical patterning and detection of multiple DNA sequences.

Authors:  Elizabeth Pavlovic; Rebecca Y Lai; Ting Ting Wu; Brian S Ferguson; Ren Sun; Kevin W Plaxco; H T Soh
Journal:  Langmuir       Date:  2008-01-09       Impact factor: 3.882

Review 8.  Bone-marrow transplantation (second of two parts).

Authors:  E D Thomas; R Storb; R A Clift; A Fefer; L Johnson; P E Neiman; K G Lerner; H Glucksberg; C D Buckner
Journal:  N Engl J Med       Date:  1975-04-24       Impact factor: 91.245

Review 9.  Bone-marrow transplantation (first of two parts).

Authors:  E Thomas; R Storb; R A Clift; A Fefer; F L Johnson; P E Neiman; K G Lerner; H Glucksberg; C D Buckner
Journal:  N Engl J Med       Date:  1975-04-17       Impact factor: 91.245

10.  CD8+ T cells from patients with acute multiple sclerosis display selective increase of adhesiveness in brain venules: a critical role for P-selectin glycoprotein ligand-1.

Authors:  Luca Battistini; Laura Piccio; Barbara Rossi; Simona Bach; Simona Galgani; Claudio Gasperini; Linda Ottoboni; Donatella Ciabini; Maria D Caramia; Giorgio Bernardi; Carlo Laudanna; Elio Scarpini; Rodger P McEver; Eugene C Butcher; Giovanna Borsellino; Gabriela Constantin
Journal:  Blood       Date:  2003-02-20       Impact factor: 22.113

View more
  79 in total

1.  Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays.

Authors:  Antoine-Emmanuel Saliba; Laure Saias; Eleni Psychari; Nicolas Minc; Damien Simon; François-Clément Bidard; Claire Mathiot; Jean-Yves Pierga; Vincent Fraisier; Jean Salamero; Véronique Saada; Françoise Farace; Philippe Vielh; Laurent Malaquin; Jean-Louis Viovy
Journal:  Proc Natl Acad Sci U S A       Date:  2010-08-02       Impact factor: 11.205

2.  Geometrical optimization of microstripe arrays for microbead magnetophoresis.

Authors:  Anders Dahl Henriksen; Noemi Rozlosnik; Mikkel Fougt Hansen
Journal:  Biomicrofluidics       Date:  2015-10-21       Impact factor: 2.800

Review 3.  Recent Developments in Magnetic Diagnostic Systems.

Authors:  Hakho Lee; Tae-Hyun Shin; Jinwoo Cheon; Ralph Weissleder
Journal:  Chem Rev       Date:  2015-08-10       Impact factor: 60.622

4.  Sampling techniques for single-cell electrophoresis.

Authors:  Christine Cecala; Jonathan V Sweedler
Journal:  Analyst       Date:  2012-01-30       Impact factor: 4.616

5.  An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo.

Authors:  Ophir Vermesh; Amin Aalipour; T Jessie Ge; Yamil Saenz; Yue Guo; Israt S Alam; Seung-Min Park; Charlie N Adelson; Yoshiaki Mitsutake; Jose Vilches-Moure; Elias Godoy; Michael H Bachmann; Chin Chun Ooi; Jennifer K Lyons; Kerstin Mueller; Hamed Arami; Alfredo Green; Edward I Solomon; Shan X Wang; Sanjiv S Gambhir
Journal:  Nat Biomed Eng       Date:  2018-07-16       Impact factor: 25.671

6.  Magnetic barcoded hydrogel microparticles for multiplexed detection.

Authors:  Ki Wan Bong; Stephen C Chapin; Patrick S Doyle
Journal:  Langmuir       Date:  2010-06-01       Impact factor: 3.882

Review 7.  Microchip-based detection of magnetically labeled cancer biomarkers.

Authors:  Melaku Muluneh; David Issadore
Journal:  Adv Drug Deliv Rev       Date:  2013-10-05       Impact factor: 15.470

8.  μHall chip for sensitive detection of bacteria.

Authors:  David Issadore; Hyun Jung Chung; Jaehoon Chung; Ghyslain Budin; Ralph Weissleder; Hakho Lee
Journal:  Adv Healthc Mater       Date:  2013-03-12       Impact factor: 9.933

9.  Diagnosis of traumatic brain injury using miRNA signatures in nanomagnetically isolated brain-derived extracellular vesicles.

Authors:  J Ko; M Hemphill; Z Yang; E Sewell; Y J Na; D K Sandsmark; M Haber; S A Fisher; E A Torre; K C Svane; A Omelchenko; B L Firestein; R Diaz-Arrastia; J Kim; D F Meaney; D Issadore
Journal:  Lab Chip       Date:  2018-10-25       Impact factor: 6.799

10.  Mechanical characterization of differentiated human embryonic stem cells.

Authors:  Gidon Ofek; Vincent P Willard; Eugene J Koay; Jerry C Hu; Patrick Lin; Kyriacos A Athanasiou
Journal:  J Biomech Eng       Date:  2009-06       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.