Literature DB >> 19012951

Calibrated automated thrombin generation and modified thromboelastometry in haemophilia A.

Joost J van Veen1, Alex Gatt, Annette E Bowyer, Peter C Cooper, Steve Kitchen, Mike Makris.   

Abstract

INTRODUCTION: Global coagulation tests may have a better relation with phenotype in haemophilia than traditional coagulation tests. These include the Calibrated Automated Thrombin generation assay (CAT) and modified thromboelastometry using low tissue factor triggering. Both have shown marked variability in thrombin generation and clot formation profiles respectively despite similar FVIII:C levels and have been suggested as means to monitor treatment. Data with modified thromboelastometry are largely limited to severe and moderate haemophiliacs. CAT measurements in haemophilia are generally performed at low TF concentrations (1 pM) because of a higher sensitivity for the intrinsic pathway at this concentration but is also sensitive for FVIII at higher concentrations (5 pM) and this has the advantage that inhibition of contact factor activation can be avoided. No formal comparison of both TF concentrations has been reported and the data on modified thromboelastometry in mild haemophilia are limited.
METHODS: In this study we compared thrombin generation at 1 and 5 pM in 57 haemophilia patients without exposure to treatment and 41 patients after treatment. We also assessed the sensitivity of thromboelastometry for haemophilia A in 29 patients. RESULTS AND
CONCLUSION: We found that CAT discriminates well between normal individuals and haemophilia patients; also FVIII:C correlates well with the ETP/peak. We found no clear advantages of measurements at 1 compared to 5 pM but found increased variation over time at 1 pM. The sensitivity of modified thromboelastometry for haemophilia A was less than CAT with abnormal measurements largely limited to severe and moderate patients. Larger studies correlating both methods with clinical outcome are required.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19012951     DOI: 10.1016/j.thromres.2008.09.011

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  9 in total

1.  Decline in platelet microparticles contributes to reduced hemostatic potential of stored plasma.

Authors:  Nena Matijevic; Yao-Wei W Wang; Vadim Kostousov; Charles E Wade; K Vinod Vijayan; John B Holcomb
Journal:  Thromb Res       Date:  2011-03-21       Impact factor: 3.944

2.  Proposal for standardized preanalytical and analytical conditions for measuring thrombin generation in hemophilia: communication from the SSC of the ISTH.

Authors:  Y Dargaud; A S Wolberg; E Gray; C Negrier; H C Hemker
Journal:  J Thromb Haemost       Date:  2017-06-28       Impact factor: 5.824

3.  Specific and global coagulation tests in patients with mild haemophilia A with a double mutation (Glu113Asp, Arg593Cys).

Authors:  Alenka Trampuš Bakija; Maruša Debeljak; Irena Preložnik Zupan; Majda Benedik Dolničar; Jernej Kovač; Janez Jazbec
Journal:  Blood Transfus       Date:  2015-05-15       Impact factor: 3.443

4.  Specific and global coagulation assays in the diagnosis of discrepant mild hemophilia A.

Authors:  Annette E Bowyer; Joost J Van Veen; Anne C Goodeve; Steve Kitchen; Michael Makris
Journal:  Haematologica       Date:  2013-06-28       Impact factor: 9.941

5.  Monitoring rFVIII prophylaxis dosing using global haemostasis assays.

Authors:  M A Al Hawaj; E J Martin; J Venitz; J C Barrett; J G Kuhn; M E Nolte; D F Brophy
Journal:  Haemophilia       Date:  2013-03-19       Impact factor: 4.287

6.  Thrombin-generating potential, plasma clot formation, and clot lysis are impaired in patients with bleeding of unknown cause.

Authors:  Stefanie Hofer; Cihan Ay; Judit Rejtö; Alisa S Wolberg; Helmuth Haslacher; Silvia Koder; Ingrid Pabinger; Johanna Gebhart
Journal:  J Thromb Haemost       Date:  2019-07-15       Impact factor: 5.824

Review 7.  Thrombin generation for monitoring hemostatic therapy in hemophilia A: A narrative review.

Authors:  Marieke J A Verhagen; Lars L F G Valke; Saskia E M Schols
Journal:  J Thromb Haemost       Date:  2022-01-28       Impact factor: 16.036

Review 8.  Biomechanics of haemostasis and thrombosis in health and disease: from the macro- to molecular scale.

Authors:  Reginald Tran; David R Myers; Jordan Ciciliano; Elaissa L Trybus Hardy; Yumiko Sakurai; Byungwook Ahn; Yongzhi Qiu; Robert G Mannino; Meredith E Fay; Wilbur A Lam
Journal:  J Cell Mol Med       Date:  2013-03-14       Impact factor: 5.310

9.  Global coagulation assays in hemophilia A: A comparison to conventional assays.

Authors:  Saman Aghighi; Anne Riddell; Christine A Lee; Simon A Brown; Edward Tuddenham; Pratima Chowdary
Journal:  Res Pract Thromb Haemost       Date:  2019-12-29
  9 in total