Literature DB >> 19012163

N95 and p100 respirator filter efficiency under high constant and cyclic flow.

Jonathan P Eshbaugh1, Paul D Gardner, Aaron W Richardson, Kent C Hofacre.   

Abstract

This study investigated the effect of high flow conditions on aerosol penetration and the relationship between penetration at constant and cyclic flow conditions. National Institute for Occupational Safety and Health (NIOSH)-approved N95 and P100 filtering facepiece respirators and cartridges were challenged with inert solid and oil aerosols. A combination of monodisperse aerosol and size-specific aerosol measurement equipment allowed count-based penetration measurement of particles with nominal diameters ranging from 0.02 to 2.9 microm. Three constant flow conditions (85, 270, and 360 L/min) were selected to match the minute, inhalation mean, and inhalation peak flows of the four cyclic flow conditions (40, 85, 115, and 135 L/min) tested. As expected, penetration was found to increase under increased constant and cyclic flow conditions. The most penetrating particle size (MPPS) generally ranged from 0.05 to 0.2 microm for P100 filters and was approximately 0.05 microm for N95 filters. Although penetration increased at the high flow conditions, the MPPS was relatively unaffected by flow. Of the constant flows tested, the flows equivalent to cyclic inhalation mean and peak flows best approximated the penetration measurements of the corresponding cyclic flows.

Mesh:

Substances:

Year:  2009        PMID: 19012163     DOI: 10.1080/15459620802558196

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  14 in total

1.  Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

Authors:  Xinjian He; Sergey A Grinshpun; Tiina Reponen; Roy McKay; Michael S Bergman; Ziqing Zhuang
Journal:  Ann Occup Hyg       Date:  2013-10-08

2.  Comparison of Simulated Workplace Protection Factors Offered by N95 and P100 Filtering Facepiece and Elastomeric Half-Mask Respirators against Particles of 10 to 400 nm.

Authors:  Xinjian He; Evanly Vo; M Horvatin; Y Liu; M Bergman; Z Zhuang
Journal:  J Nanotechnol Mater Sci       Date:  2015-09-07

3.  Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial.

Authors:  Taeho Lim; Sanghyun Lee; Jaehoon Oh; Hyunggoo Kang; Chiwon Ahn; Yeongtak Song; Juncheol Lee; Hyungoo Shin
Journal:  Biomed Res Int       Date:  2017-04-27       Impact factor: 3.411

4.  Protection afforded by respirators when performing endotracheal intubation using a direct laryngoscope, GlideScope®, and i-gel® device: A randomized trial.

Authors:  Hyunggoo Kang; Yoonje Lee; Sanghyun Lee; Yeongtak Song; Tae Ho Lim; Jaehoon Oh; Juncheol Lee; Hyungoo Shin
Journal:  PLoS One       Date:  2018-04-19       Impact factor: 3.240

5.  Performance of an N95 filtering facepiece particulate respirator and a surgical mask during human breathing: two pathways for particle penetration.

Authors:  Sergey A Grinshpun; Hiroki Haruta; Robert M Eninger; Tiina Reponen; Roy T McKay; Shu-An Lee
Journal:  J Occup Environ Hyg       Date:  2009-10       Impact factor: 2.155

6.  Viable viral efficiency of N95 and P100 respirator filters at constant and cyclic flow.

Authors:  Paul D Gardner; Jonathan P Eshbaugh; Shannon D Harpest; Aaron W Richardson; Kent C Hofacre
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

7.  Analysis of residual chemicals on filtering facepiece respirators after decontamination.

Authors:  W B Salter; K Kinney; W H Wallace; A E Lumley; B K Heimbuch; J D Wander
Journal:  J Occup Environ Hyg       Date:  2010-08       Impact factor: 2.155

Review 8.  Efficacy and safety of decontamination for N95 respirator reuse: a systematic literature search and narrative synthesis.

Authors:  Benjamin E Steinberg; Kazuyoshi Aoyama; Mark McVey; David Levin; Asad Siddiqui; Farrukh Munshey; Neil M Goldenberg; David Faraoni; Jason T Maynes
Journal:  Can J Anaesth       Date:  2020-07-27       Impact factor: 6.713

Review 9.  An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration.

Authors:  A Tcharkhtchi; N Abbasnezhad; M Zarbini Seydani; N Zirak; S Farzaneh; M Shirinbayan
Journal:  Bioact Mater       Date:  2020-08-11

10.  How does breathing frequency affect the performance of an N95 filtering facepiece respirator and a surgical mask against surrogates of viral particles?

Authors:  Xinjian He; Tiina Reponen; Roy McKay; Sergey A Grinshpun
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

View more