Literature DB >> 19011192

Supraaortic arteries: contrast material dose reduction at 3.0-T high-spatial-resolution MR angiography--feasibility study.

Anderanik Tomasian1, Noriko Salamon, Derek G Lohan, Mehdi Jalili, J Pablo Villablanca, J Paul Finn.   

Abstract

PURPOSE: To evaluate and compare the diagnostic image quality resulting from three contrast agent dose regimens for 3.0-T high-spatial-resolution three-dimensional magnetic resonance (MR) angiography of the supraaortic arteries.
MATERIALS AND METHODS: Institutional review board approval was obtained; informed consent was waived for this HIPAA-compliant study. One hundred twenty consecutive patients who underwent 3.0-T three-dimensional high-spatial-resolution contrast material-enhanced MR angiography of the supraaortic arteries with an identical acquisition protocol were assigned to either the high-dose (0.154 mmol per kilogram of body weight), intermediate-dose (0.097 mmol/kg), or low-dose (0.047 mmol/kg) group. Two readers evaluated resulting images for arterial definition, venous contamination, and arterial stenosis. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at six consistent sites. Statistical analysis was performed with the Kruskal-Wallis, Wilcoxon signed rank, and analysis of variance tests and the kappa coefficient.
RESULTS: Readers 1 and 2 scored vascular definition as excellent or sufficient for diagnosis in 1311 of 1360 segments and in 1313 of 1360 segments in the high-dose group (kappa = 0.73), in 1321 of 1354 and in 1319 of 1354 segments in the intermediate-dose group (kappa = 0.77), and in 1322 of 1350 and in 1320 of 1350 segments in the low-dose group (kappa= 0.66), respectively. Arterial occlusive disease was detected by reader 1 in 52, 27, and 98 segments in the high-, intermediate-, and low-dose groups, respectively. Arterial occlusive disease was detected by reader 2 in 48, 25, and 100 segments in high-, intermediate-, and low-dose groups, respectively. No significant difference existed among the three groups regarding arterial definition scores (reader 1, P = .21; reader 2, P = .25) and venous contamination scores (reader 1, P = .38; reader 2, P = .35). SNRs and CNRs were lower in the low-dose group (P < .01).
CONCLUSION: At 3.0 T, high-spatial-resolution MR angiography of the supraaortic arteries can be performed with contrast agent doses as low as 0.047 mmol/kg, without compromising image quality, acquisition speed, or spatial resolution. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/249/3/980/DC1http://radiology.rsnajnls.org/cgi/content/full/249/3/980/DC2. RSNA, 2008

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19011192     DOI: 10.1148/radiol.2493080209

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Decreased incidence of NSF in patients on dialysis after changing gadolinium contrast-enhanced MRI protocols.

Authors:  Diego R Martin; Saravanan K Krishnamoorthy; Bobby Kalb; Khalil N Salman; Puneet Sharma; John D Carew; Phillip A Martin; Arlene B Chapman; Gaye L Ray; Christian P Larsen; Thomas C Pearson
Journal:  J Magn Reson Imaging       Date:  2010-02       Impact factor: 4.813

2.  Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction.

Authors:  Michael P Chae; David J Hunter-Smith; Warren Matthew Rozen
Journal:  Gland Surg       Date:  2015-04

Review 3.  Noninvasive aortic imaging.

Authors:  Vinit Baliyan; Daniel Verdini; Nandini M Meyersohn
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

4.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

5.  Combined low-dose contrast-enhanced MR angiography and perfusion for acute ischemic stroke at 3T: A more efficient stroke protocol.

Authors:  K Nael; A Meshksar; B Ellingson; M Pirastehfar; N Salamon; P Finn; D S Liebeskind; J P Villablanca
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-06       Impact factor: 3.825

Review 6.  Introduction to Cardiovascular Magnetic Resonance: Technical Principles and Clinical Applications.

Authors:  Wen-Yih Isaac Tseng; Mao-Yuan Marine Su; Yao-Hui Elton Tseng
Journal:  Acta Cardiol Sin       Date:  2016-03       Impact factor: 2.672

Review 7.  Magnetic resonance angiography: current status and future directions.

Authors:  Michael P Hartung; Thomas M Grist; Christopher J François
Journal:  J Cardiovasc Magn Reson       Date:  2011-03-09       Impact factor: 5.364

8.  Multicenter, intraindividual comparison of single-dose gadobenate dimeglumine and double-dose gadopentetate dimeglumine for MR angiography of the supra-aortic arteries (the Supra-Aortic VALUE study).

Authors:  Yanjun Li; X Li; D Li; J Lu; X Xing; F Yan; Yuan Li; X Wang; R Iezzi; F De Cobelli
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-04       Impact factor: 3.825

9.  Effectiveness of MR angiography for the primary diagnosis of acute pulmonary embolism: clinical outcomes at 3 months and 1 year.

Authors:  Mark L Schiebler; Scott K Nagle; Christopher J François; Michael D Repplinger; Azita G Hamedani; Karl K Vigen; Rajkumar Yarlagadda; Thomas M Grist; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2013-04-01       Impact factor: 4.813

10.  Safety and adverse effects during 24 hours after contrast-enhanced MRI with gadobenate dimeglumine (MultiHance) in children.

Authors:  Guenther Schneider; Hellmut Schürholz; Miles A Kirchin; Arno Bücker; Peter Fries
Journal:  Pediatr Radiol       Date:  2012-11-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.