Literature DB >> 19010524

Corrosion mechanism of Ti-Cr alloys in solution containing fluoride.

Shinji Takemoto1, Masayuki Hattori, Masao Yoshinari, Eiji Kawada, Katsuhiko Asami, Yutaka Oda.   

Abstract

OBJECTIVE: The objective of this study was to clarify the influence of chromium content on surface reaction of Ti-Cr alloys in an acidic fluoride-containing saline solution.
METHODS: Four Ti-Cr alloys containing 5, 10, 15 or 20 mass% chromium were characterized in terms of dissolution of metals in an acidic fluoride-containing saline solution and surface structure by X-ray photoelectron spectroscopy and Auger electron spectroscopy.
RESULTS: Total amount of metals dissolved from each alloy decreased with increase in chromium content. The surface oxide films of Ti-Cr alloys before and after immersion in an acidic fluoride-containing saline solution consisted of titanic and chromic species, such as oxide, hydroxide, and hydrate. The [Cr]/([Ti]+[Cr]) ratio in the surface oxide film on as-polished Ti-Cr alloys was closely correlated with chromium content. However, the ratio in any alloy approximately doubled after immersion. Although thick oxide films were observed after immersion, all alloys showed a thinner oxide film than commercially pure titanium. SIGNIFICANT: In all alloys, concentration of chromic species such as oxide and hydroxide in the surface oxide film was associated with chromium content, and chromic species improved corrosion resistance to fluoride.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19010524     DOI: 10.1016/j.dental.2008.09.005

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  Electrochemical Behaviour and Galvanic Effects of Titanium Implants Coupled to Metallic Suprastructures in Artificial Saliva.

Authors:  Ana Mellado-Valero; Anna Igual Muñoz; Virginia Guiñón Pina; Ma Fernanda Sola-Ruiz
Journal:  Materials (Basel)       Date:  2018-01-22       Impact factor: 3.623

2.  Fretting Corrosion Behavior of Experimental Ti-20Cr Compared to Titanium.

Authors:  Tomofumi Sawada; Christine Schille; Atif Almadani; Jürgen Geis-Gerstorfer
Journal:  Materials (Basel)       Date:  2017-02-17       Impact factor: 3.623

3.  Influence of Sandblasting and Chemical Etching on Titanium 99.2-Dental Porcelain Bond Strength.

Authors:  Malgorzata Lubas; Jaroslaw Jan Jasinski; Anna Zawada; Iwona Przerada
Journal:  Materials (Basel)       Date:  2021-12-24       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.