Literature DB >> 19007505

Rapid analysis of cocaine and metabolites in urine using a completely automated solid-phase extraction-high-performance liquid chromatography-tandem mass spectrometry method.

Eshwar Jagerdeo1, Madeline A Montgomery, Martin Sibum, Tania A Sasaki, Marc A LeBeau.   

Abstract

A rapid, simple, and completely automated method for the analysis of cocaine and its metabolites in urine has been developed. The method utilizes online solid-phase extraction (SPE) with liquid chromatographic separation and tandem mass spectrometric detection (MS-MS). An efficient online SPE procedure was developed using Hyspheretrade mark MM anion sorbent. A gradient chromatography method with a Gemini C6-Phenyl (50 x 3.00-mm i.d., 5 microm) column was used for the separation of all compounds. Detection was by positive ion mode electrospray ionization MS-MS. Multiple reaction monitoring (MRM) was used to enhance the selectivity and sensitivity of the method. Two MRM transitions were monitored for each analyte and one transition for each internal standard. Linearity was analyte-dependent but generally ranged from 7 to 1000 ng/mL. The limits of detection for the method ranged from 3 to 23 ng/mL and the limits of quantitation ranged from 7 to 69 ng/mL. Quality control (QC) samples were analyzed for each analyte in triplicate at 50, 200, and 800 ng/mL. The bias and precision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrated bias as < 5% and % precision as < 9% for all components at each QC level.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19007505     DOI: 10.1093/jat/32.8.570

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  2 in total

1.  Electrospray Quadrupole Travelling Wave Ion Mobility Time-of-Flight Mass Spectrometry for the Detection of Plasma Metabolome Changes Caused by Xanthohumol in Obese Zucker (fa/fa) Rats.

Authors:  Samanthi I Wickramasekara; Fereshteh Zandkarimi; Jeff Morré; Jay Kirkwood; LeeCole Legette; Yuan Jiang; Adrian F Gombart; Jan F Stevens; Claudia S Maier
Journal:  Metabolites       Date:  2013-08-13

2.  Comprehensive automation of the solid phase extraction gas chromatographic mass spectrometric analysis (SPE-GC/MS) of opioids, cocaine, and metabolites from serum and other matrices.

Authors:  Oliver Lerch; Oliver Temme; Thomas Daldrup
Journal:  Anal Bioanal Chem       Date:  2014-05-02       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.