| Literature DB >> 19001728 |
C Kazner1, K Lehnberg, L Kovalova, T Wintgens, T Melin, J Hollender, W Dott.
Abstract
Direct capillary nanofiltration also in combination with an upstream powdered activated carbon treatment was tested for high quality water reuse of tertiary effluent from a municipal wastewater treatment plant. Two endocrine disruptors (BPA and EE2) and two cytostatics (CytR and 5-FU) were spiked in concentrations of 1 to 2 microg/L to evaluate the process performance. In direct NF the real total removal of the micropollutants was between 5 and 40%. Adsorption to the membrane played a major role leading to a seemingly total removal between 35 and 70%. Addition of powdered activated carbon and lignite coke dust largely reduced the influence from adsorption to the membrane and increased the total removal to >95 to 99.9% depending on the PAC type and dose. The cytostatics showed already in direct NF a very high removal due to unspecified losses. Further investigations are ongoing to understand the underlying mechanism. The PAC/NF process provided a consistently high permeate quality with respect to bulk and trace organics. IWA Publishing 2008.Entities:
Mesh:
Substances:
Year: 2008 PMID: 19001728 DOI: 10.2166/wst.2008.542
Source DB: PubMed Journal: Water Sci Technol ISSN: 0273-1223 Impact factor: 1.915