Literature DB >> 19001643

Thoracic aortic stent-grafts: utility of multidetector CT for pre- and postprocedure evaluation.

Marchelle J Bean1, Pamela T Johnson, Glen S Roseborough, James H Black, Elliot K Fishman.   

Abstract

Indications for and experience with placement of endovascular stent-grafts in the thoracic aorta are still evolving. Common pathologic conditions of the thoracic aorta that are amenable to stent placement include penetrating ulcers, aortic dissection, aortic aneurysms, aortic rupture, and congenital abnormalities. Advances in multidetector computed tomography (CT) permit high-quality two-dimensional multiplanar reformation and three-dimensional rendering, which are essential for comprehensive assessment of the thoracic aorta. The ability of multidetector CT to allow detailed evaluation in any plane or perspective enables detection of thoracic aortic disease and assessment of its relationship to normal vessels. Potential complications of endovascular stent placement include endoleaks, stent migration, pseudoaneurysms, dissection, aortic perforation, kinking, thrombosis, and coverage of vital branch vessels. It is important for the radiologist to not only detect pathologic conditions of the thoracic aorta but also to provide the referring clinician with the necessary pre- and postprocedure information to determine appropriate clinical care.

Entities:  

Mesh:

Year:  2008        PMID: 19001643     DOI: 10.1148/rg.287085055

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  6 in total

1.  Unusual complications of endovascular repair of the thoracic aorta: MDCT findings.

Authors:  T Valente; G Rossi; F Lassandro; G Rea; M Marino; G Dialetto; R Muto; M Scaglione
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

2.  "Sweet spot" for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT.

Authors:  Katherine E Maturen; Ravi K Kaza; Peter S Liu; Leslie E Quint; Shokoufeh H Khalatbari; Joel F Platt
Journal:  J Comput Assist Tomogr       Date:  2012 Jan-Feb       Impact factor: 1.826

3.  Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine.

Authors:  Nadine Abi-Jaoudeh; Neil Glossop; Michael Dake; William F Pritchard; Alberto Chiesa; Matthew R Dreher; Thomas Tang; John W Karanian; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2010-04-09       Impact factor: 3.464

4.  Positive visualization of MR-compatible nitinol stent using a susceptibility-based imaging technique.

Authors:  Caiyun Shi; Guoxi Xie; Dong Liang; Haifeng Wang; Yi Huang; Yanan Ren; Yong Xue; Hanwei Chen; Shi Su; Xin Liu
Journal:  Quant Imaging Med Surg       Date:  2019-03

5.  The role of computed tomography in pre-procedural planning of cardiovascular surgery and intervention.

Authors:  Prabhakar Rajiah; Paul Schoenhagen
Journal:  Insights Imaging       Date:  2013-08-02

6.  Three-Dimensional Visualization and Imaging of the Entry Tear and Intimal Flap of Aortic Dissection Using CT Virtual Intravascular Endoscopy.

Authors:  Yafei Qi; Xiaoyuan Ma; Gang Li; Xiangxing Ma; Qing Wang; Dexin Yu
Journal:  PLoS One       Date:  2016-10-19       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.