Literature DB >> 19000875

Dynamic contrast-enhanced CT of head and neck tumors: comparison of first-pass and permeability perfusion measurements using two different commercially available tracer kinetics models.

Sotirios Bisdas1, Giorgos Konstantinou, Katarina Surlan-Popovic, Arjang Khoshneviszadeh, Mehran Baghi, Thomas J Vogl, Tong San Koh, Martin G Mack.   

Abstract

RATIONALE AND
OBJECTIVES: To evaluate the interchangeability of perfusion parameters between two software packages for the postprocessing of dynamic contrast-enhanced (DCE) computed tomographic images of head and neck tumors.
MATERIALS AND METHODS: DCE computed tomographic images of 75 patients with head and neck tumors were postprocessed using a software package based on the maximum-slope approach and Patlak analysis, as well as a software package with deconvolution-based analysis incorporating an adiabatic approximation of tissue homogeneity (ATH) model. The evaluated perfusion parameters included blood flow (F), blood volume (v), and permeability-surface area product (PS). Region-of-interest (ROI) analysis of the tumors and the metastatic lymph nodes was performed. The perfusion parameters were compared using the Wilcoxon matched-pairs test and Bland-Altman plots.
RESULTS: One hundred fifty-two ROIs of tumors and nodes were outlined and analyzed. Moderate to good correlations were demonstrated between the various perfusion values (r = 0.56-0.72, P < .0001). The Wilcoxon test revealed a significant difference between the two methods (P < .001), with the F, v, and PS values obtained using the maximum-slope approach and Patlak analysis higher than those obtained using deconvolution-based analysis with the assumptions of the ATH model. The Bland-Altman plots for F and v values revealed a proportionality trend with outliers, which were strongly associated with the magnitudes of the parameters. Analysis of the PS values did not show any systematic bias.
CONCLUSION: There were significant differences in the perfusion parameters obtained using the two software packages, and thus, these parameters are not directly interchangeable.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19000875     DOI: 10.1016/j.acra.2008.05.021

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  11 in total

1.  Use of patient outcome endpoints to identify the best functional CT imaging parameters in metastatic renal cell carcinoma patients.

Authors:  Jill Rachel Mains; Frede Donskov; Erik Morre Pedersen; Hans Henrik Torp Madsen; Jesper Thygesen; Kennet Thorup; Finn Rasmussen
Journal:  Br J Radiol       Date:  2018-01-02       Impact factor: 3.039

2.  An empirical mathematical model applied to quantitative evaluation of thioacetamide-induced acute liver injury in rats by use of dynamic contrast-enhanced computed tomography.

Authors:  Kenya Murase; Shuichiro Kobayashi; Akihiro Kitamura; Taro Matsushita; Shigeyoshi Saito; Motoko Nishiura
Journal:  Radiol Phys Technol       Date:  2012-09-19

Review 3.  Opportunities and pitfalls of cancer imaging in clinical trials.

Authors:  Bruno Morgan
Journal:  Nat Rev Clin Oncol       Date:  2011-04-26       Impact factor: 66.675

Review 4.  CT perfusion of the liver: principles and applications in oncology.

Authors:  Se Hyung Kim; Aya Kamaya; Jürgen K Willmann
Journal:  Radiology       Date:  2014-08       Impact factor: 11.105

5.  Dynamic perfusion CT - A promising tool to diagnose pancreatic ductal adenocarcinoma.

Authors:  Inga Zaborienė; Giedrius Barauskas; Antanas Gulbinas; Povilas Ignatavičius; Saulius Lukoševičius; Kristina Žvinienė
Journal:  Open Med (Wars)       Date:  2021-02-05

6.  Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM3PARE): method comparison algorithm implementation for head and neck IGRT positional verification.

Authors:  Anuradha Roy; Clifton D Fuller; David I Rosenthal; Charles R Thomas
Journal:  BMC Med Imaging       Date:  2015-08-28       Impact factor: 1.930

Review 7.  Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation.

Authors:  G J Pelgrim; A Handayani; H Dijkstra; N H J Prakken; R H J A Slart; M Oudkerk; P M A Van Ooijen; R Vliegenthart; P E Sijens
Journal:  Biomed Res Int       Date:  2016-03-10       Impact factor: 3.411

8.  CT-perfusion measurements in pancreatic carcinoma with different kinetic models: Is there a chance for tumour grading based on functional parameters?

Authors:  Sven Schneeweiß; Marius Horger; Anja Grözinger; Konstantin Nikolaou; Dominik Ketelsen; Roland Syha; Gerd Grözinger
Journal:  Cancer Imaging       Date:  2016-12-15       Impact factor: 3.909

9.  Detection of cartilage invasion in laryngeal carcinoma with dynamic contrast-enhanced CT.

Authors:  Jan W Dankbaar; Jaap Oosterbroek; Elise A Jager; Hugo W de Jong; Cornelis P Raaijmakers; Stefan M Willems; Chris H Terhaard; Marielle E Philippens; Frank A Pameijer
Journal:  Laryngoscope Investig Otolaryngol       Date:  2017-10-31

10.  Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography.

Authors:  K A Miles; T-Y Lee; V Goh; E Klotz; C Cuenod; S Bisdas; A M Groves; M P Hayball; R Alonzi; T Brunner
Journal:  Eur Radiol       Date:  2012-02-26       Impact factor: 5.315

View more