Placement of a catheter through the struts of a previously placed stent for maintenance hemodialysis: a case report.

Rajesh Joseph1, Shyamkumar N Keshava, R S Surendrababu Narayanam, George T John.   

Abstract

Venous accesses for hemodialysis are beset with thrombosis and stenosis, often resulting in loss of central venous access. We report a case in which an alternate access was created by placement of hemodialysis catheter into the central vasculature by penetrating a stent previously placed in the stenosed right brachio-cephalic vein. To our knowledge, this is the first such report.

Entities:  

Mesh:

Year:  2008        PMID: 19000128     DOI: 10.1111/j.1525-139X.2008.00490.x

Source DB:  PubMed          Journal:  Semin Dial        ISSN: 0894-0959            Impact factor:   3.455


  1 in total

1.  Transjugular intrahepatic portocaval shunt placed through the strut of an inferior vena cava stent in a patient with Budd-Chiari syndrome: a technical modification.

Authors:  N R S Surendrababu; S N Keshava; C E Eapen; U G Zachariah
Journal:  Br J Radiol       Date:  2010-01       Impact factor: 3.039