Literature DB >> 18998699

Rapid detection of tetracyclines and their 4-epimer derivatives from poultry meat with bioluminescent biosensor bacteria.

Nina E Virolainen1, Mariël G Pikkemaat, J W Alexander Elferink, Matti T Karp.   

Abstract

Tetracycline (TC) specific luminescent bacterial biosensors were used in a rapid TC residue assay sensitized to meet the EU maximum residue limit (MRL) for TC residues in poultry muscle tissue (100 microg kg(-1)) by membrane-permeabilizing and chelating agents polymyxin B and EDTA. Sensitivities of 5 ng g(-1) for doxycycline, 7.5 ng g(-1) for chlortetracycline, and 25 ng g(-1) for tetracycline and oxytetracycline were reached. Except for doxycycline, the MRLs of these tetracyclines include their 4-epimer metabolites. In the biosensor assay, all four 4-epimers showed induction capacity and antimicrobial activity, and antimicrobial activity was also observed in the inhibition assay, although with lower efficiency than that of the corresponding parent compound in both assays. The biosensor assay is an inexpensive and rapid high-throughput screening method for the detection of 4-epimer TC residues along with their parent compounds.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18998699     DOI: 10.1021/jf801797z

Source DB:  PubMed          Journal:  J Agric Food Chem        ISSN: 0021-8561            Impact factor:   5.279


  7 in total

Review 1.  Biosensor applications in the field of antibiotic research--a review of recent developments.

Authors:  Katrin Reder-Christ; Gerd Bendas
Journal:  Sensors (Basel)       Date:  2011-10-03       Impact factor: 3.576

Review 2.  Tetracyclines in Food and Feedingstuffs: From Regulation to Analytical Methods, Bacterial Resistance, and Environmental and Health Implications.

Authors:  Fabio Granados-Chinchilla; César Rodríguez
Journal:  J Anal Methods Chem       Date:  2017-01-12       Impact factor: 2.193

3.  Highly luminescent water-dispersed silicon quantum dots for fluorometric determination of oxytetracycline in milk samples.

Authors:  Hayriye Eda Şatana Kara; Burak Demİrhan; Buket Er Demİrhan
Journal:  Turk J Chem       Date:  2020-12-16       Impact factor: 1.239

4.  Probing the in vitro cytotoxicity of the veterinary drug oxytetracycline.

Authors:  Zhenxing Chi; Rutao Liu; Hong You; Shanshan Ma; Hao Cui; Qiang Zhang
Journal:  PLoS One       Date:  2014-07-14       Impact factor: 3.240

5.  A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk.

Authors:  Mei-Yi Lu; Wei-Chen Kao; Shimshon Belkin; Ji-Yen Cheng
Journal:  Sensors (Basel)       Date:  2019-09-09       Impact factor: 3.576

Review 6.  Multiplex bioanalytical methods for food and environmental monitoring.

Authors:  Sabina Rebe Raz; Willem Haasnoot
Journal:  Trends Analyt Chem       Date:  2011-07-29       Impact factor: 12.296

7.  Flow-based regenerable chemiluminescence receptor assay for the detection of tetracyclines.

Authors:  Verena K Meyer; Claire V Chatelle; Wilfried Weber; Reinhard Niessner; Michael Seidel
Journal:  Anal Bioanal Chem       Date:  2020-01-16       Impact factor: 4.142

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.