Literature DB >> 1899739

Detection of bullous lung disease: conventional radiography vs digital storage phosphor radiography.

K M Buckley1, C M Schaefer, R Greene, S Agatston, J Fay, H J Llewellyn, H E Mrose, J R Rubens.   

Abstract

The detection of fine linear contours and altered aeration are requirements for the radiologic diagnosis of bullous lung disease and are severe measures of the spatial and contrast resolution of chest imaging systems. We compared plain film radiography with five postprocessing algorithms of storage phosphor digital radiography (2144 x 1744 x 10 bit matrix with 0.2-mm pixel size) in the detection of CT-proved bullous lung disease (35 patients and 25 normal control subjects). Receiver-operating-characteristic analysis of 2160 observations by six interpreters was done to evaluate the observers' performance. By analysis of variance (p less than .05), we found that the default digital algorithm and the three edge-enhancing algorithms of high and medium frequencies performed less well than plain films did, but the differences fell short of statistical significance. Gray-scale reversal was the only digital algorithm that performed significantly less well than plain films did. We conclude that any differences between digital algorithms and plain films in the detection of bullous lung disease were too small to be detected in this study. Any difference between the two methods in providing clinically important, diagnostic information is likely to be insignificant.

Entities:  

Mesh:

Year:  1991        PMID: 1899739     DOI: 10.2214/ajr.156.3.1899739

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

Review 1.  Chest imaging within the radiology department by means of photostimulable phosphor computed radiography: a review.

Authors:  H Blume; R G Jost
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

2.  Diagnosis of IPA in HIV: the role of the chest X-ray and radiologist.

Authors:  Uta Zaspel; David W Denning; Arne J Lemke; Reginald Greene; Dirk Schürmann; Georg Maschmeyer; Markus Ruhnke; Raoul Herbrecht; Patricia Ribaud; Olivier Lortholary; Harmien Zonderland; Klaus F Rabe; Rainer Röttgen; Roland Bittner; Klaus Neumann; Joerg W Oestmann
Journal:  Eur Radiol       Date:  2004-08-11       Impact factor: 5.315

3.  The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries.

Authors:  Shimasadat Miri; Sandra Mehralizadeh; Donya Sadri; Mahmood Reza Kalantar Motamedi; Parisa Soltani
Journal:  Imaging Sci Dent       Date:  2015-09-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.