Literature DB >> 18996706

The role of technetium-99m hexakis-2-methoxyisobutyl isonitrile in the detection of neoplastic lung lesions.

Mario Santini1, Alfonso Fiorello, Luigi Mansi, Pier Francesco Rambaldi, Giovanni Vicidomini, Luigi Busiello, Gaetana Messina, Paola Nargi.   

Abstract

OBJECTIVE: Our goal was to determine the role of technetium-99m hexakis-2-methoxyisobutyl isonitrile ((99m)Tc-MIBI) in the detection of neoplastic lung lesions.
MATERIALS AND METHODS: We prospectively studied 79 consecutive patients with indeterminate lung lesion between January 2006 and September 2007. All patients were submitted to (99m)Tc-MIBI single-photon emission chest tomography (SPECT) before invasive diagnostic procedure. Qualitative analysis was performed to evaluate SPECT images in order to localize abnormal activity in the radiologically demonstrated lesion. In addition, semiquantitative analysis was made by calculating tumor/contralateral normal lung ratio (T/N). Finally, the scintigraphic findings were correlated to the histopathological diagnosis obtained by invasive procedure or confirmation of instrumental exams.
RESULTS: Sixty patients had a malignant lesion: 44 squamous cell carcinoma, 7 adenocarcinomas, 4 large cell carcinoma, 1 small cell lung cancer, and 4 metastases. The mean size+/-standard deviation of malignant nodules was 3.9+/-1.61 cm (range 1.5-5.5 cm). Nineteen patients had a benign disease. The mean size+/-standard deviation of benign nodules was 3.3+/-1.71 cm (range 2-6 cm). (99m)Tc-MIBI SPECT delineated focal lesions with an increase in tracer accumulation in 55/60 malignant lesions; in 5/60 malignant lesions was negative. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 91%, 73%, 91%, and 73%, respectively. In patients with neoplastic lesion, the mean T/N ratio value+/-standard deviation was 1.72+/-0.35 whereas in patients with benign lesions was 1.14+/-0.25. Semiquantitative analysis showed that for a T/N value >1.23, the value of sensitivity, specificity, PPV, and PNV were 91%, 84%, 94%, and 76%, respectively (ROC curve). Metastatic mediastinal lymph nodes were found in 3/57 patients. (99m)Tc-MIBI SPECT showed a specificity and PPV of 100% in the detection of mediastinal lymph nodes with sensitivity, and PNV of 66% and 97%, respectively. Age, sex, histological type, and size of lesion did not affect the SPECT results.
CONCLUSION: Our experiences seem to confirm that (99m)Tc-MIBI SPECT is a reliable diagnostic tool in the finding of lung cancer particularly cases in which radiological evaluation is indeterminate.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18996706     DOI: 10.1016/j.ejcts.2008.09.033

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  5 in total

1.  Lung 99mTc-MIBI scintigraphy: impact on diagnosis of solitary pulmonary nodule.

Authors:  Katarina Nikoletic; Silvija Lucic; Andrea Peter; Violeta Kolarov; Radmila Zeravica; Dolores Srbovan
Journal:  Bosn J Basic Med Sci       Date:  2011-08       Impact factor: 3.363

2.  Preoperative nodal staging of non-small cell lung cancer using 99mTc-sestamibi spect/ct imaging.

Authors:  Juliana Muniz Miziara; Euclides Timóteo da Rocha; José Elias Abrão Miziara; Gustavo Fabene Garcia; Maria Izilda Previato Simões; Marco Antônio Lopes; Lígia Maria Kerr; Carlos Alberto Buchpiguel
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

3.  Descending necrotizing mediastinitis in the elderly patients.

Authors:  Antonio Mazzella; Mario Santagata; Atirge Cecere; Ettore La Mart; Alfonso Fiorelli; Gianpaolo Tartaro; Domenico Tafuri; Domenico Testa; Edoardo Grella; Fabio Perrotta; Andrea Bianco; Gennaro Mazzarella; Mario Santini
Journal:  Open Med (Wars)       Date:  2016-11-19

4.  Recurrent hyperparathyroidism due to parathyroid and pulmonary tumors showing features of parathyroid adenoma.

Authors:  Ryosuke Miyauchi; Takayuki Yamada; Reiko Kumano; Yoshio Aida; Masayuki Takagi
Journal:  Radiol Case Rep       Date:  2020-06-18

Review 5.  Diagnostic Performances of 99mTc-Methoxy Isobutyl Isonitrile Scan in Predicting the Malignancy of Lung Lesions: A Meta-Analysis.

Authors:  Shuxin Zhang; Yang Liu
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.