Literature DB >> 18995937

Multichannel SEMG in clinical gait analysis: a review and state-of-the-art.

Carlo Frigo1, Paolo Crenna.   

Abstract

BACKGROUND: Application of surface electromyography (SEMG) to the clinical evaluation of neuromuscular disorders can provide relevant "diagnostic" contributions in terms of nosological classification, localization of focal impairments, detection of pathophysiological mechanisms, and functional assessment.
METHODS: The present review article elaborates on: (i) the technical aspects of the myoelectric signals acquisition within a protocol of clinical gait analysis (multichannel recording, surface vs. deep probes, electrode placing, encumbrance effects), (ii) the sequence of procedures for the subsequent data processing (filtering, averaging, normalization, repeatability control), and (iii) a set of feasible strategies for the final extraction of clinically useful information.
FINDINGS: Relevant examples of SEMG application to functional diagnosis are provided.
INTERPRETATION: Emphasis is given to the key role of SEMG along with kinematic and kinetic analysis, for non-invasive assessment of relevant pathophysiological mechanisms potentially hindering the gait function, such as changes in passive muscle-tendon properties (peripheral non-neural component), paresis, spasticity, and loss of selectivity of motor output in functionally antagonist muscles.

Entities:  

Mesh:

Year:  2008        PMID: 18995937     DOI: 10.1016/j.clinbiomech.2008.07.012

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  24 in total

1.  Trunk and hip muscle activity in early walkers with and without cerebral palsy--a frequency analysis.

Authors:  Laura A Prosser; Samuel C K Lee; Mary F Barbe; Ann F VanSant; Richard T Lauer
Journal:  J Electromyogr Kinesiol       Date:  2010-05-15       Impact factor: 2.368

2.  Electromyographic characteristics of gait impairment in cervical spondylotic myelopathy.

Authors:  Ailish Malone; Dara Meldrum; John Gleeson; Ciaran Bolger
Journal:  Eur Spine J       Date:  2013-08-02       Impact factor: 3.134

3.  Variations in Patterns of Muscle Activity Observed in Participants Walking in Everyday Environments: Effect of Different Surfaces.

Authors:  Julien Lebleu; Ross Parry; Camille Bertouille; Marine de Schaetzen; Philippe Mahaudens; Laura Wallard; Christine Detrembleur
Journal:  Physiother Can       Date:  2021       Impact factor: 1.039

4.  Walking speed measurement technology: A review.

Authors:  Yohanna MejiaCruz; Jean Franco; Garret Hainline; Stacy Fritz; Zhaoshuo Jiang; Juan M Caicedo; Benjamin Davis; Victor Hirth
Journal:  Curr Geriatr Rep       Date:  2021-01-20

5.  Classification of rhythmic locomotor patterns in electromyographic signals using fuzzy sets.

Authors:  Timothy A Thrasher; John S Ward; Stanley Fisher
Journal:  J Neuroeng Rehabil       Date:  2011-12-08       Impact factor: 4.262

6.  Multi-scale complexity analysis of muscle coactivation during gait in children with cerebral palsy.

Authors:  Wen Tao; Xu Zhang; Xiang Chen; De Wu; Ping Zhou
Journal:  Front Hum Neurosci       Date:  2015-07-22       Impact factor: 3.169

7.  A comparison land-water environment of maximal voluntary isometric contraction during manual muscle testing through surface electromyography.

Authors:  Romualdo Castillo-Lozano; Antonio Ignacio Cuesta-Vargas
Journal:  BMC Sports Sci Med Rehabil       Date:  2013-12-16

8.  The gait pattern is not impaired in subjects with external snapping hip: a comparative cross-sectional study.

Authors:  Julie S Jacobsen; Uwe G Kersting; Michael S Rathleff; Ole Simonsen; Kjeld Søballe; Michael Ulrich
Journal:  BMC Musculoskelet Disord       Date:  2013-07-19       Impact factor: 2.362

Review 9.  Hybrid soft computing systems for electromyographic signals analysis: a review.

Authors:  Hong-Bo Xie; Tianruo Guo; Siwei Bai; Socrates Dokos
Journal:  Biomed Eng Online       Date:  2014-02-03       Impact factor: 2.819

10.  Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications.

Authors:  Alvaro Muro-de-la-Herran; Begonya Garcia-Zapirain; Amaia Mendez-Zorrilla
Journal:  Sensors (Basel)       Date:  2014-02-19       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.