Literature DB >> 18990651

Sensitivity of accelerometry to assess balance control during sit-to-stand movement.

Wim G M Janssen1, Duygu Geler Külcü, Herwin L D Horemans, Henk J Stam, Johannes B J Bussmann.   

Abstract

Accelerometry has the potential to measure balance, defined as high-frequency body sway, ambulatorily in a simple and inexpensive way. The aim of this study was to determine and compare the sensitivity of accelerometric balance parameters during the sit-to-stand (STS) movement. Eleven healthy subjects (four males, 28.2 +/-7.9 years) and 31 patients with stroke (21 males; 63.3+/-12.8 years) were included. The healthy subjects performed STS movements in four conditions with different levels of difficulty. Data of the patients were compared 1) with healthy subjects, 2) between patient subgroups, and 3) between different phases of recovery to assess the sensitivity of accelerometry for differences in balance control. Accelerometers were attached to the trunk, and force plate measurements were simultaneously done in the healthy subjects. Main outcome measures were root mean square (rms) and area under the curve (AUC) derived from the high-frequency component of the transversal acceleration signal of the trunk. In all comparisons there was a significant difference in AUC data ( p < 0.05), and AUC appeared to be more sensitive than rms. Variability in AUC was not completely or mainly the result of changes and differences in the duration of the STS movement. As a conclusion, accelerometry is a potentially valuable technique to measure balance during the STS movement.

Entities:  

Mesh:

Year:  2008        PMID: 18990651     DOI: 10.1109/TNSRE.2008.2003386

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  7 in total

1.  A comparative study for performance evaluation of sit-to-stand task with body worn sensor and existing laboratory methods.

Authors:  Rahul Soangra; Thurmon E Lockhart
Journal:  Biomed Sci Instrum       Date:  2012

2.  An evaluation of the 30-s chair stand test in older adults: frailty detection based on kinematic parameters from a single inertial unit.

Authors:  Nora Millor; Pablo Lecumberri; Marisol Gómez; Alicia Martínez-Ramírez; Mikel Izquierdo
Journal:  J Neuroeng Rehabil       Date:  2013-08-01       Impact factor: 4.262

3.  Study of acceleration of center of mass during sit-to-stand and stand-to-sit in patients with stroke.

Authors:  Eunjin Na; Hyesun Hwang; Youngkeun Woo
Journal:  J Phys Ther Sci       Date:  2016-09-29

4.  Effectiveness of a muticomponent workout program integrated in an evidence based multimodal program in hyperfrail elderly patients: POWERAGING randomized clinical trial protocol.

Authors:  Manuel González-Sánchez; Antonio Ignacio Cuesta-Vargas; María Del Mar Rodríguez González; Elvira Díaz Caro; Germán Ortega Núñez; Alejandro Galán-Mercant; Juan José Bedoya Belmonte
Journal:  BMC Geriatr       Date:  2019-06-21       Impact factor: 3.921

5.  Using a body-fixed sensor to identify subclinical gait difficulties in older adults with IADL disability: maximizing the output of the timed up and go.

Authors:  Aner Weiss; Anat Mirelman; Aron S Buchman; David A Bennett; Jeffrey M Hausdorff
Journal:  PLoS One       Date:  2013-07-29       Impact factor: 3.240

6.  Differences in trunk accelerometry between frail and non-frail elderly persons in functional tasks.

Authors:  Alejandro Galán-Mercant; Antonio I Cuesta-Vargas
Journal:  BMC Res Notes       Date:  2014-02-21

7.  Differences in Trunk Accelerometry Between Frail and Nonfrail Elderly Persons in Sit-to-Stand and Stand-to-Sit Transitions Based on a Mobile Inertial Sensor.

Authors:  Alejandro Galán-Mercant; Antonio I Cuesta-Vargas
Journal:  JMIR Mhealth Uhealth       Date:  2013-08-16       Impact factor: 4.773

  7 in total