Literature DB >> 18986954

Maximum accuracy evaluation scheme for wireless saw delay-line sensors.

J H Kuypers1, L M Reindl, S Tanaka, M Esashi.   

Abstract

This paper describes an evaluation scheme that prevents phase ambiguity of surface acoustic wave (SAW) delay-line sensors. Although it is well-known that phase evaluation yields accuracies of 150~1500 times higher than time-delay evaluation, the problem of phase ambiguity has prevented phase evaluation of sensors operating over a range larger than 2 pi. This paper addresses this unsolved problem with a complete strategy. Furthermore, the existence of an optimum choice of the relative reflector positions on the sensor is shown. The presented relations enable the design of maximum accuracy SAW delay-line sensors.

Mesh:

Year:  2008        PMID: 18986954     DOI: 10.1109/TUFFC.2008.840

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Surface acoustic wave devices for chemical sensing and microfluidics: A review and perspective.

Authors:  David B Go; Masood Z Atashbar; Zeinab Ramshani; Hsueh-Chia Chang
Journal:  Anal Methods       Date:  2017-06-13       Impact factor: 2.896

2.  Maximum measurement range and accuracy of SAW reflective delay line sensors.

Authors:  Zehua Zheng; Tao Han; Peng Qin
Journal:  Sensors (Basel)       Date:  2015-10-20       Impact factor: 3.576

Review 3.  Reader Architectures for Wireless Surface Acoustic Wave Sensors.

Authors:  Fabian Lurz; Thomas Ostertag; Benedict Scheiner; Robert Weigel; Alexander Koelpin
Journal:  Sensors (Basel)       Date:  2018-05-28       Impact factor: 3.576

4.  Multi-Channel Real-Time Condition Monitoring System Based on Wideband Vibration Analysis of Motor Shafts Using SAW RFID Tags Coupled with Sensors.

Authors:  Pau Caldero; Dominik Zoeke
Journal:  Sensors (Basel)       Date:  2019-12-07       Impact factor: 3.576

Review 5.  Surface Acoustic Wave (SAW) Sensors: Physics, Materials, and Applications.

Authors:  Debdyuti Mandal; Sourav Banerjee
Journal:  Sensors (Basel)       Date:  2022-01-21       Impact factor: 3.576

  5 in total