A 1-D dual-electrode CMUT array for intracardiac echocardiography (ICE) with a center frequency of 8 MHz has been designed, fabricated, and used to demonstrate the potential of dual-electrode CMUTs. Using a dual-electrode CMUT, 9 dB higher receive signal level is obtained over the 6 dB fractional bandwidth as compared with a conventional CMUT with an identical center electrode biased close to its collapse voltage. Because the same device shows a 7.4 dB increase in maximum pressure output, 16.4 dB overall improvement in transduction performance has been achieved as compared with conventional CMUT. A net peak output pressure of 1.6 MPa on the dual-electrode CMUT membrane with tone burst excitation at 12 MHz is also reported. The frequency response of the dual-electrode CMUT is similar to that of a conventional CMUT with the same membrane geometry with about 15% increase in the center frequency. Monostatic operation of dual-electrode CMUTs shows that the high performance of the transducer is applicable in typical pulse-echo imaging mode of operation. With dynamic shaping of the CMUT membrane to optimize the transmit-and-receive modes of operation separately during each pulse-echo cycle, dual-electrode CMUT is a highly competitive alternative to its piezoelectric counterparts.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18986882      PMCID: PMC2916999          DOI: 10.1109/TUFFC.933

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  9 in total

1.  A new regime for operating capacitive micromachined ultrasonic transducers.

Authors:  Baris Bayram; Edward Haeggström; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-09       Impact factor: 2.725

2.  Capacitive micromachined ultrasonic transducer design for high power transmission.

Authors:  Baris Bayram; Omer Oralkan; A Sanli Ergun; Edward Haeggström; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

3.  3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

Authors:  David T Yeh; Omer Oralkan; Ira O Wygant; Matthew O'Donnell; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

4.  Fast scanning probe for ophthalmic echography using an ultrasound motor.

Authors:  Riccardo Carotenuto; Giosuè Caliano; Alessandro Caronti; Alessandro Savoia; Massimo Pappalardo
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-11       Impact factor: 2.725

5.  Experimental characterization of collapse-mode CMUT operation.

Authors:  Omer Oralkan; Baris Bayram; Goksen G Yaralioglu; A Sanli Ergun; Mario Kupnik; David T Yeh; Ira O Wygant; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-08       Impact factor: 2.725

6.  Comparison of conventional and collapsed region operation of capacitive micromachined ultrasonic transducers.

Authors:  Yongli Huang; Edward Haeggström; Baris Bayram; Xuefeng Zhuang; Arif Sanli Ergun; Ching-Hsiang Cheng; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-10       Impact factor: 2.725

7.  Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers.

Authors:  Selim Olcum; Muhammed N Senlik; Abdullah Atalar
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

8.  CMUTS with dual-electrode structure for improved transmit and receive performance.

Authors:  Rasim O Guldiken; Jeff McLean; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-02       Impact factor: 2.725

9.  Surface micromachined capacitive ultrasonic transducers.

Authors:  I Ladabaum; X Jin; H T Soh; A Atalar; B T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

  9 in total
  4 in total

1.  A nonlinear lumped model for ultrasound systems using CMUT arrays.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-10       Impact factor: 2.725

Review 2.  Photoacoustic tomography: fundamentals, advances and prospects.

Authors:  Junjie Yao; Lihong V Wang
Journal:  Contrast Media Mol Imaging       Date:  2011 Sep-Oct       Impact factor: 3.161

3.  Dual-electrode CMUT with non-uniform membranes for high electromechanical coupling coefficient and high bandwidth operation.

Authors:  Rasim O Guldiken; Jaime Zahorian; F Y Yamaner; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-06       Impact factor: 2.725

Review 4.  Emerging technologies for assembly of microscale hydrogels.

Authors:  Umut Atakan Gurkan; Savas Tasoglu; Doga Kavaz; Melik C Demirel; Utkan Demirci
Journal:  Adv Healthc Mater       Date:  2012-03       Impact factor: 9.933

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.