Literature DB >> 18981839

Application accuracy of computed tomography-based, image-guided navigation of temporal bone.

Promod Pillai1, Steffen Sammet, Mario Ammirati.   

Abstract

OBJECTIVE: Although frameless stereotactic techniques have become indispensable in neurosurgery, their technical complexity requires careful definition and evaluation. Navigation is of particular concern when it is applied to approach a complex, tight surgical area like the temporal bone, where every millimeter is important. Theoretically, the temporal bone is an ideal location in which to use image-guided navigation because its bony construct precludes pre- and intraoperative shift. In this context, the feasibility of using a navigational system is determined by the system's accuracy and by the spatial characteristics of the targets. Literature addressing the accuracy of image guidance techniques in temporal bone surgery is relatively sparse. Accuracy of these systems within the temporal bone is still under investigation. We investigated the application accuracy of computed tomography-based, frameless, image-guided navigation to identify various bony structures in the temporal bone via a retrosigmoid approach.
METHODS: In a total of 10 operations, we performed a retrosigmoid approach simulating operative conditions on either side of 5 whole, fresh cadaveric heads. Six titanium microscrews were implanted around the planned craniotomy site as permanent bone reference markers before the surgical procedure. High-resolution computed tomographic scans were obtained (slice thickness, 0.6-mm, contiguous non-overlapping slices; gantry setting, 0 degrees; scan window diameter, 225 mm; pixel size, >0.44 x 0.44). We used a Stryker navigation system (Stryker Instruments, Kalamazoo, MI) for intraoperative navigation. External and internal targets were selected for calculation of navigation accuracy.
RESULTS: The system calculated target registration error to be 0.48 +/- 0.21 mm, and the global accuracies (navigation accuracies) were calculated using external over-the-skull and internal targets within the temporal bone. Overall navigation accuracy was 0.91 +/- 0.28 mm; for reaching internal targets within temporal bone, accuracy was 0.94 +/- 0.22 mm; and for external targets, accuracy was 0.83 +/- 0.11 mm. Ninety-five percent of targets could be reached within 1.4 mm of their actual position.
CONCLUSION: Using high-resolution computed tomography and bone-implanted reference markers, frameless navigation can be as accurate as frame-based stereotaxy in providing a guide to maximize safe surgical approaches to the temporal bone. Although error-free navigation is not possible with the submillimetric accuracy required by direct anatomic contouring of tiny structures within temporal bone, it still provides a road map to maximize safe surgical exposure.

Mesh:

Year:  2008        PMID: 18981839     DOI: 10.1227/01.NEU.0000316429.19314.67

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  14 in total

1.  Real-time imaging with the o-arm for skull base applications: a cadaveric feasibility study.

Authors:  Shaan M Raza; Alfred P See; Michael Lim
Journal:  J Neurol Surg B Skull Base       Date:  2012-10

2.  Endoscope-assisted microsurgical transoral approach to the anterior craniovertebral junction compressive pathologies.

Authors:  Massimiliano Visocchi; Francesco Doglietto; Giuseppe Maria Della Pepa; Giuseppe Esposito; Giuseppe La Rocca; Concezio Di Rocco; Giulio Maira; Eduardo Fernandez
Journal:  Eur Spine J       Date:  2011-05-10       Impact factor: 3.134

3.  Image-guided, microsurgical topographic anatomy of the endolymphatic sac and vestibular aqueduct via a suboccipital retrosigmoid approach.

Authors:  Roberto Colasanti; Al-Rahim Abbasali Tailor; Jun Zhang; Mario Ammirati
Journal:  Neurosurg Rev       Date:  2015-04-25       Impact factor: 3.042

4.  Prospects and limitations of different registration modalities in electromagnetic ENT navigation.

Authors:  Eric Soteriou; Juergen Grauvogel; Roland Laszig; Tanja Daniela Grauvogel
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-05-05       Impact factor: 2.503

5.  Assessment of the OsteoMark-Navigation System for Oral and Maxillofacial Surgery.

Authors:  Zachary S Peacock; John C Magill; Brad J Tricomi; Brian A Murphy; Vladimir Nikonovskiy; Nobuhiko Hata; Laurent Chauvin; Maria J Troulis
Journal:  J Oral Maxillofac Surg       Date:  2015-03-19       Impact factor: 1.895

6.  Percutaneous access to the petrous apex in vitro using customized micro-stereotactic frames based on image-guided surgical technology.

Authors:  George B Wanna; Ramya Balachandran; Omid Majdani; Jason Mitchell; Robert F Labadie
Journal:  Acta Otolaryngol       Date:  2009-08-25       Impact factor: 1.494

7.  Quantitative and qualitative analysis of the working area obtained by endoscope and microscope in pterional and orbitozigomatic approach to the basilar artery bifurcation using computed tomography based frameless stereotaxy: A cadaver study.

Authors:  Venko Filipce; Mario Ammirati
Journal:  Asian J Neurosurg       Date:  2015 Apr-Jun

8.  Quantitative error analysis for computer assisted navigation: a feasibility study.

Authors:  Ö Güler; M Perwög; F Kral; F Schwarm; Z R Bárdosi; G Göbel; W Freysinger
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Validation of exposure visualization and audible distance emission for navigated temporal bone drilling in phantoms.

Authors:  Eduard H J Voormolen; Peter A Woerdeman; Marijn van Stralen; Herke Jan Noordmans; Max A Viergever; Luca Regli; Jan Willem Berkelbach van der Sprenkel
Journal:  PLoS One       Date:  2012-07-25       Impact factor: 3.240

10.  Minimally invasive multiport surgery of the lateral skull base.

Authors:  Igor Stenin; Stefan Hansen; Meike Becker; Georgios Sakas; Dieter Fellner; Thomas Klenzner; Jörg Schipper
Journal:  Biomed Res Int       Date:  2014-07-02       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.