Literature DB >> 18979815

EEG to MRI registration based on global and local similarities of MRI intensity distributions.

Ziga Spiclin1, Arne Hans, Frank H Duffy, Simon K Warfield, Bostjan Likar, Franjo Pernus.   

Abstract

In this paper, a novel method for EEG to MRI registration is proposed. Initial registration is achieved by extracting and matching symmetry planes of MRI and EEG data, followed by iterative registration based on minimizing a cost function. Comparison of the intensity distributions of the whole MR image and MRI voxels around a head surface point yields global similarities, while the comparison of intensity distributions of MRI voxels around corresponding EEG points, which reflects the head's sagittal symmetry, yields local similarities. Therefore, when the EEG points are registered to the MR image, maximal global and local similarities should be obtained. The cost function, incorporating global and local similarities, was the sum of Kullback-Leibler divergences between corresponding intensity distributions. The proposed method was evaluated on clinical MRI data with simulated EEG data, yielding mean registration error of 0.48 +/- 0.33 mm, while with real EEG data an average root-mean-square point-to-surface error of 2.27 +/- 0.02 mm was obtained.

Mesh:

Year:  2008        PMID: 18979815      PMCID: PMC2690649          DOI: 10.1007/978-3-540-85988-8_91

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  11 in total

1.  An algorithmic overview of surface registration techniques for medical imaging.

Authors:  M A Audette; F P Ferrie; T M Peters
Journal:  Med Image Anal       Date:  2000-09       Impact factor: 8.545

2.  Co-registration of EEG and MRI data using matching of spline interpolated and MRI-segmented reconstructions of the scalp surface.

Authors:  C Lamm; C Windischberger; U Leodolter; E Moser; H Bauer
Journal:  Brain Topogr       Date:  2001       Impact factor: 3.020

3.  Automatic alignment of EEG/MEG and MRI data sets.

Authors:  D Kozinska; F Carducci; K Nowinski
Journal:  Clin Neurophysiol       Date:  2001-08       Impact factor: 3.708

Review 4.  EEG source imaging.

Authors:  Christoph M Michel; Micah M Murray; Göran Lantz; Sara Gonzalez; Laurent Spinelli; Rolando Grave de Peralta
Journal:  Clin Neurophysiol       Date:  2004-10       Impact factor: 3.708

5.  Registration and real-time visualization of transcranial magnetic stimulation with 3-D MR images.

Authors:  Quentin Noirhomme; Matthieu Ferrant; Yves Vandermeeren; Etienne Olivier; Benoît Macq; Olivier Cuisenaire
Journal:  IEEE Trans Biomed Eng       Date:  2004-11       Impact factor: 4.538

6.  Estimation of the accuracy of a surface matching technique for registration of EEG and MRI data.

Authors:  H J Huppertz; M Otte; C Grimm; R Kristeva-Feige; T Mergner; C H Lücking
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1998-05

7.  Automatic detection of the mid-sagittal plane in 3-D brain images.

Authors:  B A Ardekani; J Kershaw; M Braun; I Kanno
Journal:  IEEE Trans Med Imaging       Date:  1997-12       Impact factor: 10.048

8.  Evaluation of MRI-MEG/EEG co-registration strategies using Monte Carlo simulation.

Authors:  K D Singh; I E Holliday; P L Furlong; G F Harding
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1997-02

9.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

10.  Scalp-recorded EEG localization in MRI volume data.

Authors:  B H Brinkmann; T J O'Brien; M A Dresner; T D Lagerlund; F W Sharbrough; R A Robb
Journal:  Brain Topogr       Date:  1998       Impact factor: 3.020

View more
  2 in total

1.  Multi-Resolution Graph Based Volumetric Cortical Basis Functions From Local Anatomic Features.

Authors:  Damon E Hyde; Jurriaan Peters; Simon K Warfield
Journal:  IEEE Trans Biomed Eng       Date:  2019-03-13       Impact factor: 4.538

2.  Anisotropic partial volume CSF modeling for EEG source localization.

Authors:  Damon E Hyde; Frank H Duffy; Simon K Warfield
Journal:  Neuroimage       Date:  2012-05-29       Impact factor: 6.556

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.