Literature DB >> 18979414

Effectiveness of a novel home-based testing device for the detection of rupture of membranes.

Jacob Bornstein1, Gonen Ohel, Yoram Sorokin, Kathleen Z Reape, Oleg Shnaider, Hadar Kessary-Shoham, Ella Ophir.   

Abstract

We evaluated the ability of a testing panty liner (TPL) embedded with a pH/ammonia indicator polymer to differentiate amniotic fluid leakage from urine. A multicenter, open-label study in which 339 pregnant women (age 18 to 45 years, minimum 16 weeks' gestation, presenting with unexplained vaginal wetness) were enrolled. The TPL was worn and the results read by the subject and a health care provider (HCP) who was blinded to the subject's reading. Results were compared with the standard clinical diagnosis, as determined by direct visualization of vaginal pooling, crystallization (ferning), and nitrazine tests, performed by a second blinded HCP. Subject experience with the test was assessed with a brief questionnaire. The TPL accurately detected 154 of the 161 subjects found to have amniotic fluid leakage by the standard diagnosis; thus, the sensitivity of the TPL was 95.65%. The specificity was 84.46% (% true negative readings), as the TPL demonstrated a negative result for 125 of the 148 subjects whose clinical diagnosis was negative for amniotic fluid leakage. The overall agreement between the TPL readings of the clinician and that of the subject was 97.40%. The TPL is a reliable test to determine the presence of amniotic fluid leakage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18979414     DOI: 10.1055/s-0028-1095183

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  3 in total

1.  Amniotic fluid volume and composition after fetal membrane resection in late-gestation sheep.

Authors:  Robert A Brace; Cecilia Y Cheung
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-11       Impact factor: 1.232

2.  The Prevalence and Payer Costs of Potentially Avoidable Emergent Care Visits for Suspected Amniotic Membrane Rupture in Pregnant Women.

Authors:  Christine Ferro; Bruce S Pyenson; Jocelyn Lau; Mona Kelkar; Nancy Phillips; Chi-Wei Lu; Percy Yeung; Gloria Bachmann
Journal:  Am Health Drug Benefits       Date:  2018-07

Review 3.  Vision Amniotic Leak Detector (ALD) to Eliminate Amniotic Fluid Leakage as a Cause of Vaginal Wetness in Pregnancy: A NICE Medical Technology Guidance.

Authors:  A F Ray; S C Peirce; A R Wilkes; G Carolan-Rees
Journal:  Appl Health Econ Health Policy       Date:  2015-10       Impact factor: 2.561

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.