Literature DB >> 18979413

Three-dimensional placental volume measurements between 11 and 13 weeks' gestation.

Eliezer Burstein1, Eyal Sheiner, Reli Hershkovitz.   

Abstract

We sought to determine whether three-dimensional (3D) placental volume measurements can be assessed in normal pregnancies between 11 and 13 weeks' gestation with good intraobserver accuracy. Twenty normal pregnancies were included. Placental volume was determined twice, using the virtual organ computer-aided analysis method. Three-dimensional placental volume measurements were performed by a single physician. Patients with multiple pregnancies, first-trimester bleeding, and abnormal placental appearance were excluded. Intraobserver reliability was evaluated by kappa analysis, and Student T test was performed for continuous variables. Mean placental volume (MPV) was 67.5 +/- 26.7 mL (3) between 11 and 13 weeks' gestation. No significant differences were noted between the two examinations performed (MPV of 67.5 +/- 26.7 mL (3) during the first versus 65.6 +/- 29.1 mL (3) during the second examination; p = 0.826). Moreover, the intraobserver agreement was excellent as indicated by kappa of 0.8. Placental volume can be assessed by 3D sonography between 11 and 13 weeks' gestation with minimal deviations. Nevertheless, the broad variability in placental volume with a wide standard deviation makes its clinical significance questionable.

Entities:  

Mesh:

Year:  2008        PMID: 18979413     DOI: 10.1055/s-0028-1095188

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  3 in total

1.  FIGO (international Federation of Gynecology and obstetrics) initiative on fetal growth: best practice advice for screening, diagnosis, and management of fetal growth restriction.

Authors:  Nir Melamed; Ahmet Baschat; Yoav Yinon; Apostolos Athanasiadis; Federico Mecacci; Francesc Figueras; Vincenzo Berghella; Amala Nazareth; Muna Tahlak; H David McIntyre; Fabrício Da Silva Costa; Anne B Kihara; Eran Hadar; Fionnuala McAuliffe; Mark Hanson; Ronald C Ma; Rachel Gooden; Eyal Sheiner; Anil Kapur; Hema Divakar; Diogo Ayres-de-Campos; Liran Hiersch; Liona C Poon; John Kingdom; Roberto Romero; Moshe Hod
Journal:  Int J Gynaecol Obstet       Date:  2021-03       Impact factor: 3.561

2.  Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study.

Authors:  Marcus J Rijken; William E Moroski; Suporn Kiricharoen; Noaeni Karunkonkowit; Gordon Stevenson; Eric O Ohuma; J Alison Noble; Stephen H Kennedy; Rose McGready; Aris T Papageorghiou; François H Nosten
Journal:  Malar J       Date:  2012-01-05       Impact factor: 2.979

3.  Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

Authors:  Cécile Fanget; Céline Chauleur; Amandine Stadler; Emilie Presles; Marie-Noëlle Varlet; Jean-Christophe Gris; Tiphaine Raia-Barjat
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

  3 in total