Real-time motion-adaptive delivery (MAD) using binary MLC: I. Static beam (topotherapy) delivery.

Weiguo Lu1.   

Abstract

Intra-fraction target motion hits the fundamental basis of IMRT where precise target positions are assumed. Real-time motion compensation is necessary to ensure that the same dose is delivered as planned. Strategies for conventional IMRT delivery for moving targets by dynamic multi-leaf collimators (MLC) tracking are well published. Binary MLC-based IMRT,such as TomoTherapy , requires synchronized motion of MLC, the couch and the gantry, which suggests a unique motion management strategy. Thanks to it sultra-fast leaf response and fast projection rate, real-time motion compensation for binary MLC-based IMRT is feasible. Topotherapy is a new IMRT delivery technique, which can be implemented in commercial helical TomoTherapy machines using only fixed gantry positions. In this paper, we present a novel approach for TopoTherapy delivery that adjusts for moving targets without additional hardware and control requirement. This technique uses the planned leaf sequence but rearranges the projection and leaf indices. It does not involve time-consuming operations, such as reoptimization. Unlike gating or breath hold-based methods, this technique can achieve nearly a 100% duty cycle with little breath control. Unlike dynamic MLC-based tracking methods, this technique requires neither the whole target motion trajectory nor the velocity of target motion. Instead, it only requires instantaneous target positions, which greatly simplifies the system implementation. Extensive simulations, including the worst-case scenarios, validated the presented technique to be applicable to relatively regular or mild irregular respirations. The delivered dose conforms well to the target, and significant margin reduction can be achieved provided that accurate, real-time tumor localization is available.

Entities:  

Mesh:

Year:  2008        PMID: 18978446     DOI: 10.1088/0031-9155/53/22/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

Authors:  Yujie Chi; Chenyang Shen; Bin Li; You Zhang; Ming Yang; Michael Folkert; Xun Jia
Journal:  Phys Med Biol       Date:  2019-11-21       Impact factor: 3.609

2.  A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

Authors:  Y Chi; N H Rezaeian; C Shen; Y Zhou; W Lu; M Yang; R Hannan; X Jia
Journal:  Phys Med Biol       Date:  2017-07-07       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.