Literature DB >> 18973982

Compliance of abdominal aortic aneurysms before and after stenting with tissue doppler imaging: evolution during follow-up and correlation with aneurysm diameter.

Anne Long1, Laurence Rouet, Fabien Vitry, Jean Noel Albertini, Claude Marcus, Claude Clement.   

Abstract

Usual imaging after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) consists of AAA diameter monitoring and endoleak detection. Among additional predictor parameters previously proposed to help clinicians in better identifying subgroups of AAA still at risk of rupture, AAA wall motion after EVAR has been studied, but its value was not clearly established. Tissue Doppler imaging (TDI) is an ultrasonographic modality which allows wall motion measurements along an arterial segment. The aim of the current study was to analyze AAA wall motion with TDI before and after EVAR and to describe its evolution in patients with more than 1 month of follow-up. Twenty-five consecutive patients undergoing EVAR between February 2005 and June 2007 gave informed consent to be prospectively investigated with the TDI system before EVAR and at each visit during follow-up. The mean (SD) follow-up was 13.7 (9.7) months. Maximum mean segmental dilation (MMSD), segmental compliance, dilation at maximum diameter, pressure strain elastic modulus (Ep), and stiffness were compared between three periods (before stenting, before discharge, and at last follow-up), and their relation with AAA diameter was analyzed. A significant decrease in AAA compliance was immediately observed after successful EVAR and remained stable during later follow-up. On the other hand, AAA diameter progressively decreased along time and was statistically lower at the last control compared to the initial value. MMSD, segmental compliance, and dilation at maximum diameter were positively related to AAA diameter. This means that the larger the AAA diameter after stenting, the higher the value for these parameters can be expected. On the contrary, percentage of AAA diameter decrease and percentage of MMSD decrease were not related after successful EVAR. There was no parallelism between loss in compliance and diameter decrease along time, and there is not a unique pattern of AAA diameter and compliance evolution after EVAR. Even if comparison between patients without and with endoleak was weak due to the small sample of the latter group (five patients with endoleak), compliance tended to be greater in case of endoleak. AAA wall motion after successful EVAR reflects complex interactions between all the components of the stented aneurysm which evolve over time, including true compliance of the aneurysm wall itself; intra-aneurysm sac pressure with possible different effects for peak, mean, and pulse pressures; remodeling of the thrombus; stiffness characteristics of the graft; and systemic pressure. Combining simultaneous MMSD records with actual intrasaccular pressure measurements in patients with and without endoleak would improve our understanding of the clinical pulsatility mechanism within AAA after EVAR.

Entities:  

Mesh:

Year:  2008        PMID: 18973982     DOI: 10.1016/j.avsg.2008.08.006

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  6 in total

1.  Fabricating mechanically improved silk-based vascular grafts by solution control of the gel-spinning process.

Authors:  Maria Rodriguez; Jonathan A Kluge; Daniel Smoot; Matthew A Kluge; Daniel F Schmidt; Christopher R Paetsch; Peter S Kim; David L Kaplan
Journal:  Biomaterials       Date:  2019-10-23       Impact factor: 12.479

2.  Quantification of hemodynamics in abdominal aortic aneurysms during rest and exercise using magnetic resonance imaging and computational fluid dynamics.

Authors:  Andrea S Les; Shawn C Shadden; C Alberto Figueroa; Jinha M Park; Maureen M Tedesco; Robert J Herfkens; Ronald L Dalman; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2010-02-09       Impact factor: 3.934

Review 3.  Imaging of Abdominal Aortic Aneurysm: the present and the future.

Authors:  Hao Hong; Yunan Yang; Bo Liu; Weibo Cai
Journal:  Curr Vasc Pharmacol       Date:  2010-11       Impact factor: 2.719

Review 4.  Arterial Stiffness Alterations and Inflammatory Response Following Endovascular Aortic Repair: Based on a Presentation at the 2013 VEITH Symposium, November 19-23, 2013 (New York, NY, USA).

Authors:  Konstantinos G Moulakakis; Spyridon N Mylonas; John Kakisis; Nikolaos P E Kadoglou; Ioannis Papadakis; George S Sfyroeras; Constantine C N Antonopoulos; George Mantas; Ignatios Ikonomidis; Christos D Liapis
Journal:  Aorta (Stamford)       Date:  2015-04-01

Review 5.  A literature review of the numerical analysis of abdominal aortic aneurysms treated with endovascular stent grafts.

Authors:  David Roy; Claude Kauffmann; Sébastien Delorme; Sophie Lerouge; Guy Cloutier; Gilles Soulez
Journal:  Comput Math Methods Med       Date:  2012-09-06       Impact factor: 2.238

6.  Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft.

Authors:  Efstratios Georgakarakos; Christos Argyriou; George S Georgiadis; Miltos K Lazarides
Journal:  Front Surg       Date:  2016-01-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.