| Literature DB >> 18972157 |
Paul Tait1, Umeer Waheed, Suzanne Bell.
Abstract
The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfully removed without the complication of bleeding in a patient unsuitable for a general anesthetic.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18972157 DOI: 10.1007/s00270-008-9461-y
Source DB: PubMed Journal: Cardiovasc Intervent Radiol ISSN: 0174-1551 Impact factor: 2.740