Literature DB >> 18971567

Defibrillation testing and early neurologic outcome.

Remzi Karaoguz1, Timuein Altln, E Cem Atbasoglu, Canan Isikay, Bahar Güraslan, Omer Akyürek, Osman Beton, Kutay Vurgun, Nezih Yüceman, Kazim Soylu, Muharrem Güldal.   

Abstract

During implantable cardioverter-defibrillator (ICD) implantation, ventricular defibrillation testing (DFT) is considered a standard procedure. This procedure often requires multiple ventricular fibrillation (VF) inductions. These repeated short episodes of circulatory arrest with global cerebral ischemia may cause neurological damage. In the present study, patients undergoing initial ICD implantation and limited induction of VF for defibrillation safety margin testing were evaluated for pre- and postoperative cognitive and neurologic functions. In addition, the serum neuron specific enolase (NSE) level, which is a biochemical marker of cerebral injury, was evaluated. The study was performed on 16 patients undergoing initial elective transvenous insertion of an ICD. A neurologic examination and cognitive assessment tests were performed 24 to 48 hours before and after ICD. NSE was determined before (NSE 1) and at the end of the surgery (NSE 2), as well as 2 hours (NSE 3), 24 hours (NSE 4), and 48 hours (NSE 5) after implantation. A total of 29 internal shocks (average, 1.8 +/- 0.4) with energy ranging from 14 to 41 J (mean, 20 +/- 5; median, 20 J ) were delivered in the ICD group patients. In one patient, 3 external (50, 200 and 360 J) shocks were required for fast VT induced during ICD lead positioning. The mean duration of VF was 10 +/- 4 seconds and the mean cumulative time in VF was 16 +/- 5 seconds. The mean recovery time between VFs was 5.3 +/- 0.6 minutes. NSE levels were not different from the baseline at any time point in the patients of the group that completed the 48-hour observation period (P > 0.05). The patients did not report any new neurological symptoms after ICD implantation, and repeat examination after the procedure showed no abnormal findings other than those detected in the previous one. There were no statistically significant differences between the preoperative and postoperative scores obtained in the cognitive assessment. Single or two VF inductions and the brief arrest of cerebral circulation during ICD implantation are not associated with permanent neurological injury. However, further studies are needed to confirm this finding.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18971567     DOI: 10.1536/ihj.49.553

Source DB:  PubMed          Journal:  Int Heart J        ISSN: 1349-2365            Impact factor:   1.862


  3 in total

Review 1.  [Implantation of cardioverter-defibrillators. How much anesthesia is necessary?].

Authors:  T Sellmann; M Winterhalter; U Herold; P Kienbaum
Journal:  Anaesthesist       Date:  2010-06       Impact factor: 1.041

2.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01

3.  Utility of neuron-specific enolase in traumatic brain injury; relations to S100B levels, outcome, and extracranial injury severity.

Authors:  Eric Peter Thelin; Emma Jeppsson; Arvid Frostell; Mikael Svensson; Stefania Mondello; Bo-Michael Bellander; David W Nelson
Journal:  Crit Care       Date:  2016-09-08       Impact factor: 9.097

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.