Literature DB >> 18970895

Hg(II)-imprinted thiol-functionalized mesoporous sorbent micro-column preconcentration of trace mercury and determination by inductively coupled plasma optical emission spectrometry.

Zhefeng Fan1.   

Abstract

Hg(II)-imprinting thiol-functionalized mesoporous sorbent was prepared by a sol-gel method and characterized by X-ray diffraction (XRD), FT-IR spectroscopy and nitrogen gas adsorption-desorption. The static adsorption capacity of the Hg(II)-imprinted and non-imprinted sorbent was 78.5 and 26.6mgg(-1), respectively. The breakthrough capacity was 4.46mgg(-1), and the relative selectivity coefficient for Hg(II) in the presence of Cd and Pb was 3.3 and 3.9, respectively. A new method using a micro-column packed with Hg(II)-imprinting thiol-functionalized mesoporous sorbent has been developed for preconcentration of trace mercury prior to its determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The effects of pH, sample flow rate and volume, elution solution and interfering ions on the recovery of the analyte have been investigated. The limit of detection was 0.39ngml(-1) with a concentration factor of 150 times. The developed method has been applied to the determination of trace mercury in some biological and environmental samples with satisfactory results. The accuracy was assessed through recovery experiments and analysis of certified reference material.

Entities:  

Year:  2006        PMID: 18970895     DOI: 10.1016/j.talanta.2006.03.021

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Synthesis and application of ion-imprinted polymer nanoparticles for the extraction and preconcentration of mercury in water and food samples employing cold vapor atomic absorption spectrometry.

Authors:  Mahmoud Roushani; Shahryar Abbasi; Hossein Khani
Journal:  Environ Monit Assess       Date:  2015-08-29       Impact factor: 2.513

2.  Novel Imprinted Polymer for the Preconcentration of Cadmium with Determination by Inductively Coupled Plasma Mass Spectrometry.

Authors:  Vedat Yilmaz; Hayriye Yilmaz; Zikri Arslan; Jerzy Leszczynski
Journal:  Anal Lett       Date:  2016-05-24       Impact factor: 2.329

3.  Selective solid phase extraction of copper using a new Cu(II)-imprinted polymer and determination by inductively coupled plasma optical emission spectroscopy (ICP-OES).

Authors:  Vedat Yilmaz; Zikri Arslan; Orhan Hazer; Hayriye Yilmaz
Journal:  Microchem J       Date:  2014-05-01       Impact factor: 4.821

4.  Solid phase extraction of inorganic mercury using 5-phenylazo-8-hydroxyquinoline and determination by cold vapor atomic fluorescence spectroscopy in natural water samples.

Authors:  Mirna Daye; Baghdad Ouddane; Jalal Halwani; Mariam Hamzeh
Journal:  ScientificWorldJournal       Date:  2013-12-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.