On-line preconcentration of pharmaceutical residues from large volume water samples using short reversed-phase monolithic cartridges coupled to LC-UV-ESI-MS.

Jonathan Bones1, Kevin Thomas, Pavel N Nesterenko, Brett Paull.   

Abstract

A simplified preconcentration method for a range of ultra-trace level pharmaceuticals in natural waters has been developed. Solid phase extraction was performed on-line using a micro-reversed-phase monolithic silica column, allowing for very rapid trace enrichment from large volume (500ml) samples with minimal sample handling. Acceptable recoveries of >70% were obtained for the majority of compounds investigated and the monolithic columns could be washed and conditioned on-line with no sample carryover and used reproducibly for up to eight extractions each. The on-line SPE-LC-UV method was coupled to electrospray ionisation ion trap mass spectrometry (ESI-MS) to increase both selectivity and specificity. Detection limits were determined in spiked river and tap water samples and found to lie in the low ng/l region using sample volumes of 500ml, loaded at a flow rate of 10ml/min, and therefore, were suitable for ultra trace analysis.

Entities:  

Year:  2006        PMID: 18970889     DOI: 10.1016/j.talanta.2006.02.026

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Development of an ultra fast online-solid phase extraction (SPE) liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS) based approach for the determination of drugs in pharmacokinetic studies.

Authors:  Nils Helge Schebb; Bora Inceoglu; Tristan Rose; Karen Wagner; Bruce D Hammock
Journal:  Anal Methods       Date:  2011-01-01       Impact factor: 2.896

2.  Occurrence of pharmaceutical compounds in wastewater process streams in Dublin, Ireland.

Authors:  Clair Lacey; Shaik Basha; Anne Morrissey; John M Tobin
Journal:  Environ Monit Assess       Date:  2011-04-09       Impact factor: 2.513

3.  Automatic analytical approach for the determination of 12 illicit drugs and nicotine metabolites in wastewater using on-line SPE-UHPLC-MS/MS.

Authors:  Jingyuan Wang; Likai Qi; Chenzhi Hou; Tingting Zhang; Mengyi Chen; Haitao Meng; Mengxiang Su; Hui Xu; Zhendong Hua; Youmei Wang; Bin Di
Journal:  J Pharm Anal       Date:  2021-01-22

4.  Tools for Early Prediction of Drug Loading in Lipid-Based Formulations.

Authors:  Linda C Alskär; Christopher J H Porter; Christel A S Bergström
Journal:  Mol Pharm       Date:  2015-12-07       Impact factor: 4.939

5.  Assessment of the Presence of Pharmaceutical Compounds in Seawater Samples from Coastal Area of Gran Canaria Island (Spain).

Authors:  Cristina Afonso-Olivares; M Esther Torres-Padrón; Zoraida Sosa-Ferrera; José Juan Santana-Rodríguez
Journal:  Antibiotics (Basel)       Date:  2013-05-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.