Literature DB >> 18970548

Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration.

Baoxin Li1, Dongmei Wang, Jiagen Lv, Zhujun Zhang.   

Abstract

A flow-injection chemiluminescence (CL) system is proposed for simultaneous determination of Co(2+) and Cu(2+) using partial least squares (PLS) calibration. This method is based on the fact that both Co(2+) and Cu(2+) catalyse the CL reaction of luminol-H(2)O(2), and that their kinetic characteristics of Co(2+) and Cu(2+) are significantly different in the luminol-H(2)O(2) system. The CL intensity was measured and recorder at different reaction times of luminol-H(2)O(2)Co(2+)Cu(2+), and the obtained data were processed by the chemometric approach of partial least squares. The experimental calibration set was composed of 16 sample solutions using an orthogonal calibration design for two component mixtures. The proposed method offers the potential advantages of high sensitivity, simplicity and rapidity for Co(2+) and Cu(2+) determination, and was successfully applied to the simultaneous determination of both analytes in real water sample. The present paper demonstrated that the simultaneous determination of two metal ions without any prior separation has been possible using flow-injection CL system.

Entities:  

Year:  2005        PMID: 18970548     DOI: 10.1016/j.talanta.2005.09.017

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Quenching of Luminol Fluorescence at Nano-Bio Interface: Towards the Development of an Efficient Energy Transfer System.

Authors:  Vikash Kumar Sonu; Sivaprasad Mitra
Journal:  J Fluoresc       Date:  2018-12-06       Impact factor: 2.217

2.  A novel chemiluminescence assay of organophosphorous pesticide quinalphos residue in vegetable with luminol detection.

Authors:  Haoyu Hu; Xiaoyu Liu; Feng Jiang; Xin Yao; Xiaocheng Cui
Journal:  Chem Cent J       Date:  2010-06-24       Impact factor: 4.215

3.  Simultaneous determination of captopril and hydrochlorothiazide by time-resolved chemiluminescence with artificial neural network calibration.

Authors:  Han-Chun Yao; Min Sun; Xiao-Feng Yang; Zhen-Zhong Zhang; Hua Li
Journal:  J Pharm Anal       Date:  2012-01-30

4.  Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system.

Authors:  Xiaoyu Liu; Aifang Li; Baohui Zhou; Chaokun Qiu; Hongmin Ren
Journal:  Chem Cent J       Date:  2009-07-01       Impact factor: 4.215

5.  Sensitive assay for carvedilol in tablets and spiked human plasma using a flow-injection chemiluminometric method.

Authors:  Nawal Al Arfaj; Heba H Abdine; Maha A Sultan
Journal:  Int J Biomed Sci       Date:  2007-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.