Literature DB >> 18970536

Pressure effects on resolution in ion mobility spectrometry.

Mahmoud Tabrizchi1, Fereshteh Rouholahnejad.   

Abstract

This paper explains the effect of pressure on separation factor, resolving power (defined based on a single peak), and resolution (defined based on two adjacent peaks) in ion mobility spectrometry. IMS spectra were recorded at various pressures ranging from 39 hPa (29Torr) up to atmospheric pressure and various ion gates ranging from 50 to 225 micros. The results show that the IMS peaks shift perfectly linear with pressure so that separation factors remain unaffected by pressure. However, pressure has strong influence on resolving power and resolution. Reducing pressure at constant pulse width decreases the resolving power and resolution. On the other hand, the decrease in resolution can be compensated by shortening the ion pulse width since reducing pressure results in a higher ion current.

Year:  2005        PMID: 18970536     DOI: 10.1016/j.talanta.2005.09.016

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  An effective approach for coupling direct analysis in real time with atmospheric pressure drift tube ion mobility spectrometry.

Authors:  Joel D Keelor; Prabha Dwivedi; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2014-06-06       Impact factor: 3.109

2.  Improved analytical performance of negative 63Ni ion mobility spectrometry for on-line measurement of propofol using dichloromethane as dopant.

Authors:  Qinghua Zhou; Lei Hua; Changsong Wang; Enyou Li; Haiyang Li
Journal:  J Am Soc Mass Spectrom       Date:  2014-10-21       Impact factor: 3.109

3.  Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry.

Authors:  James N Dodds; Jody C May; John A McLean
Journal:  Anal Chem       Date:  2017-10-30       Impact factor: 6.986

Review 4.  Review on ion mobility spectrometry. Part 2: hyphenated methods and effects of experimental parameters.

Authors:  R Cumeras; E Figueras; C E Davis; J I Baumbach; I Gràcia
Journal:  Analyst       Date:  2015-03-07       Impact factor: 4.616

5.  Investigation of the Complete Suite of the Leucine and Isoleucine Isomers: Toward Prediction of Ion Mobility Separation Capabilities.

Authors:  James N Dodds; Jody C May; John A McLean
Journal:  Anal Chem       Date:  2016-12-21       Impact factor: 6.986

6.  High-pressure ion mobility spectrometry.

Authors:  Eric J Davis; Prabha Dwivedi; Maggie Tam; William F Siems; Herbert H Hill
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.