Literature DB >> 18970285

MCM-41 mesoporous material modified carbon paste electrode for the determination of cardiac troponin I by anodic stripping voltammetry.

Huishi Guo1, Nongyue He, Shuxun Ge, Di Yang, Jinan Zhang.   

Abstract

An anodic stripping voltammetric method for the determination of cardiac troponin I (cTnI) at a MCM-41 mesoporous material modified carbon paste electrode (MCM-MCPE) was investigated. The test was based on the dual monoclonal antibody "sandwich" principle using colloidal gold as a labeled substrate. Four main steps were carried out to obtain the analytical signal, i.e. electrode preparation, immunoreaction, silver enhancement, and anodic stripping voltammetric detection. The anodic stripping peak current increased linearly with the concentration of cTnI over the range of 0.8-5.0ng/ml. A detection limit of 0.5ng/ml was obtained. The established method was applied to detect cTnI in acute myocardial infarction (AMI) samples using routine enzyme-linked immunoadsorbent assay (ELISA) for comparison analysis, and good results were obtained.

Entities:  

Year:  2005        PMID: 18970285     DOI: 10.1016/j.talanta.2005.04.067

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

Review 1.  Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer.

Authors:  James F Rusling; Challa V Kumar; J Silvio Gutkind; Vyomesh Patel
Journal:  Analyst       Date:  2010-07-08       Impact factor: 4.616

Review 2.  Nanomaterials-based electrochemical immunosensors for proteins.

Authors:  James F Rusling
Journal:  Chem Rec       Date:  2012-01-30       Impact factor: 6.771

3.  Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels.

Authors:  Karin Y Chumbimuni-Torres; Zong Dai; Nastassia Rubinova; Yun Xiang; Ernö Pretsch; Joseph Wang; Eric Bakker
Journal:  J Am Chem Soc       Date:  2006-10-25       Impact factor: 15.419

4.  Nanomaterials and biomaterials in electrochemical arrays for protein detection.

Authors:  James F Rusling; Gregory W Bishop; Nhi Doan; Fotios Papadimitrakopoulos
Journal:  J Mater Chem B       Date:  2014-01-07       Impact factor: 6.331

Review 5.  Electrochemical immunosensors for detection of cancer protein biomarkers.

Authors:  Bhaskara V Chikkaveeraiah; Ashwinkumar A Bhirde; Nicole Y Morgan; Henry S Eden; Xiaoyuan Chen
Journal:  ACS Nano       Date:  2012-08-06       Impact factor: 15.881

6.  Immobilization of HRP in Mesoporous Silica and Its Application for the Construction of Polyaniline Modified Hydrogen Peroxide Biosensor.

Authors:  Chien-Chung Chen; Jing-Shan Do; Yesong Gu
Journal:  Sensors (Basel)       Date:  2009-06-12       Impact factor: 3.576

  6 in total