Literature DB >> 18970088

Novel potentiometric copper (II) selective membrane sensors based on cyclic tetrapeptide derivatives as neutral ionophores.

Saad S M Hassan1, Eman M Elnemma, Ayman H K Mohamed.   

Abstract

Two novel membrane sensors sensitive and reasonably selective for Cu(2+) ions are described. These are based on the use of newly synthesized cyclic tetrapeptide derivatives as neutral ionophores and sodium tetraphenylborate (NaTPB) as an anionic excluder in plasticized PVC membranes. The sensors exhibit fast and stable near-Nernstian response over the concentration range 1.0x10(-6)moll(-1) to 1.0x10(-2)moll(-1) Cu(2+) with a cationic slope of 30.2-25.9mV per decade at pH 4.5-7 with a lower detection limit of 0.05-0.13mugml(-1). Effects of plasticizers, lipophilic salts and various foreign common ions are tested. The sensors display long life-span, long term stability, high reproducibility, and short response time. Selectivity of both sensors is significantly high for Cu(2+) over Fe(3+), Al(3+), Zn(2+), Cd(2+), Hg(2+), Ni(2+), Co(2+), Mn(2+), alkaline earth and alkali metal ions. The sensors are used for direct measurement of copper content in different rocks and industrial wastewater samples from electroplating factories. The results agree fairly well with data obtained using atomic absorption spectrometry.

Entities:  

Year:  2005        PMID: 18970088     DOI: 10.1016/j.talanta.2005.01.007

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Potentiometric detection and removal of copper using porphyrins.

Authors:  Dana Vlascici; Iuliana Popa; Vlad A Chiriac; Gheorghe Fagadar-Cosma; Horia Popovici; Eugenia Fagadar-Cosma
Journal:  Chem Cent J       Date:  2013-07-06       Impact factor: 4.215

Review 2.  Biosensors for the detection of circulating tumour cells.

Authors:  Clotilde Costa; Miguel Abal; Rafael López-López; Laura Muinelo-Romay
Journal:  Sensors (Basel)       Date:  2014-03-10       Impact factor: 3.576

3.  Single-Piece Solid Contact Cu2+-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore.

Authors:  Abd El-Galil E Amr; Mohamed A Al-Omar; Ayman H Kamel; Elsayed A Elsayed
Journal:  Molecules       Date:  2019-03-06       Impact factor: 4.411

4.  Trace level monitoring of Cu(II) ion using CuS particles based membrane electrochemical sensor.

Authors:  Dipak Kumar Gupta; Shova Neupane; Harish Chand Yadav; Vivek Subedi; Sanjay Singh; Ram Jeewan Yadav; Anju Kumari Das; Brahamdeo Yadav; Krishna Badan Nakarmi; Nabin Karki; Amar Prasad Yadav
Journal:  Heliyon       Date:  2021-05-29

5.  Thiopental and Phenytoin as Novel Ionophores for Potentiometric Determination of Lead (II) Ions.

Authors:  Nashwa M H Rizk; Samah S Abbas; Salem M Hamza; Yasser M Abd El-Karem
Journal:  Sensors (Basel)       Date:  2009-03-13       Impact factor: 3.576

6.  Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode.

Authors:  Aysenur Birinci; Hilal Eren; Fatih Coldur; Emine Coskun; Muberra Andac
Journal:  J Food Drug Anal       Date:  2016-04-12       Impact factor: 6.157

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.