Literature DB >> 18969996

Trace and ultratrace analysis methods for the determination of phosphorus by flow-injection techniques.

Shoji Motomizu1, Zhen-Hai Li.   

Abstract

Trace (< or =1 mg/l or 30 microM) and ultratrace (< or =1 microg/l or 30 nM) analysis methods for phosphorus determination by flow-injection analysis are reviewed. Most of the methods cited in this review are fundamentally based on the reaction of orthophosphate with molybdate to form heteropoly acids, such as molybdenum yellow and molybdenum blue, and some of the methods are based on the formation of such secondary reactions as ion associates and their aggregates with bulky cations, such as cationic dyes and quaternary ammonium ions. The heteropoly acids themselves can be measured by spectrophotometry, and the ion associate formed with a cationic dye, Malachite Green (MG), can be measured based on the coloration of MG. Light scattering detection methods can be used for measuring the aggregates of ion associates formed with bulky cations. Highly sensitive detection of phosphorus can be accomplished by fluorophotometry; Rhodamine B (RB) and its analogues react with molybdophosphate to form ion associates, which shows fluorescence quenching of RB: LOD is about 5 nM. The detection method based on the chemiluminescence of luminal oxidized with molybdophosphoric acids is probably the most sensitive of all the detection methods reported so far: LOD of the method is as low as 1nM. The LOD of the molybdenum blue method can be improved by using a liquid core waveguide: LOD is 0.5 nM.

Entities:  

Year:  2005        PMID: 18969996     DOI: 10.1016/j.talanta.2004.12.056

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Optical recognition of anions by ruthenium(II)-bipyridine-calix[4]arene system.

Authors:  Paulpandian Muthu Mareeswaran; Eththilu Babu; Seenivasan Rajagopal
Journal:  J Fluoresc       Date:  2013-05-29       Impact factor: 2.217

2.  A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples.

Authors:  Stanislawa Koronkiewicz; Mihaela Trifescu; Lech Smoczynski; Harsha Ratnaweera; Slawomir Kalinowski
Journal:  Environ Monit Assess       Date:  2018-02-12       Impact factor: 2.513

3.  Reducing the channel diameter of polydimethylsiloxane fluidic chips made by a 3D-printed sacrificial template and their application for flow-injection analysis.

Authors:  Tomohisa Yamashita; Tatsuya Muramoto
Journal:  Anal Sci       Date:  2022-02-15       Impact factor: 2.081

4.  Colorimetric Phosphate Detection Using Organic DFB Laser Based Absorption Spectroscopy.

Authors:  Thilo Pudleiner; Elias Sutter; Jörg Knyrim; Christian Karnutsch
Journal:  Micromachines (Basel)       Date:  2021-11-30       Impact factor: 2.891

  4 in total