Literature DB >> 18969950

Application of a flow type quartz crystal microbalance immunosensor for real time determination of cattle bovine ephemeral fever virus in liquid.

Yuan-Guey Lee1, Ku-Shang Chang.   

Abstract

Bovine ephemeral fever (BEF) is a viral disease of cattle. A flow type quartz crystal microbalance (QCM) immunosensor was developed for the real time determination BEF virus (BEFV) that is suitable for clinical point-case diagnosis. Self-assembled monolayer (SAM) of thiols and sulphides by the cystamine-glutaraldehyde method was used for the immobilization of BEFV monoclonal antibody on the gold surface of a quartz crystal microbalance (QCM). A positive correlation was found between the virus concentration and frequency changes (R(2)=0.9962) on this QCM system. The reproducible rates for the 50 and 10mug/mL samples were 4 and 13.9%, respectively. There was no interference from non-specifically adsorbed phage. Using this flow type QCM immunosensor, BEFV could specifically be detected with sensitivity comparable to a conventional enzyme-linked immunosorbent assay (ELISA). The measurement could be obtained directly, within several minutes, rather than hours as required visualizing the results of ELISA. In addition, the observation of reproducible and constant changes after successive additions of BEFV suggests that a QCM immunosensor in a flow cell could be developed for automated or continuous real time operation.

Entities:  

Year:  2005        PMID: 18969950     DOI: 10.1016/j.talanta.2004.09.011

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  7 in total

1.  Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol.

Authors:  Sunil K Arya; Ganna Chornokur; Manju Venugopal; Shekhar Bhansali
Journal:  Biosens Bioelectron       Date:  2010-03-18       Impact factor: 10.618

2.  Detection of cartilage oligomeric matrix protein using a quartz crystal microbalance.

Authors:  Shih-Han Wang; Chi-Yen Shen; Ting-Chan Weng; Pin-Hsuan Lin; Jia-Jyun Yang; I-Fen Chen; Shyh-Ming Kuo; Shwu-Jen Chang; Yuan-Kun Tu; Yu-Hsien Kao; Chih-Hsin Hung
Journal:  Sensors (Basel)       Date:  2010-12-20       Impact factor: 3.576

3.  Light assisted antibody immobilization for bio-sensing.

Authors:  Bartolomeo Della Ventura; Luigi Schiavo; Carlo Altucci; Rosario Esposito; Raffaele Velotta
Journal:  Biomed Opt Express       Date:  2011-10-28       Impact factor: 3.732

4.  New approach to a practical quartz crystal microbalance sensor utilizing an inkjet printing system.

Authors:  Yusuke Fuchiwaki; Masato Tanaka; Yoji Makita; Toshihiko Ooie
Journal:  Sensors (Basel)       Date:  2014-10-30       Impact factor: 3.576

5.  Development of a recombinase polymerase amplification combined with lateral-flow dipstick assay for detection of bovine ephemeral fever virus.

Authors:  Peili Hou; Guimin Zhao; Hongmei Wang; Chengqiang He; Yanjun Huan; Hongbin He
Journal:  Mol Cell Probes       Date:  2017-12-26       Impact factor: 2.365

6.  The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance.

Authors:  Thamara M Peduru Hewa; Gregory A Tannock; David E Mainwaring; Sally Harrison; John V Fecondo
Journal:  J Virol Methods       Date:  2009-07-21       Impact factor: 2.014

7.  Microgravimetric immunosensor for direct detection of aerosolized influenza A virus particles.

Authors:  Thomas W Owen; Rabih O Al-Kaysi; Christopher J Bardeen; Quan Cheng
Journal:  Sens Actuators B Chem       Date:  2007-04-24       Impact factor: 7.460

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.