Literature DB >> 18969927

Spectrophotometric simultaneous determination of nitroaniline isomers by orthogonal signal correction-partial least squares.

Jahanbakhsh Ghasemi1, Ali Niazi.   

Abstract

The simultaneous determination of nitroaniline isomer mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removes the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 200-500nm range for 21 different mixtures of nitroaniline isomers. Calibration matrices were containing 1-21, 1-15 and 1-18mugml(-1) of m-nitroaniline, o-nitroaniline and p-nitroaniline, respectively. The RMSEP for m-nitroaniline, o-nitroaniline and p-nitroaniline with OSC and without OSC were 0.6567, 0.2692, and 0.3134, and 1.3818, 1.2181, and 0.3953, respectively. This procedure allows the simultaneous determination of nitroaniline isomers in real matrix samples and good reliability of the determination was proved.

Entities:  

Year:  2005        PMID: 18969927     DOI: 10.1016/j.talanta.2004.08.052

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Simultaneous spectrophotometric determination of trace amount of polycyclic aromatic hydrocarbons in water samples after magnetic solid-phase extraction by using projection pursuit regression.

Authors:  Jahan B Ghasemi; E Zolfonoun
Journal:  Environ Monit Assess       Date:  2012-06-12       Impact factor: 2.513

2.  Ultrasound-assisted ionic liquid-based microextraction combined with least squares support vector machines regression for the simultaneous determination of aluminum, gallium, and indium in water and coal samples.

Authors:  Jahan B Ghasemi; Ehsan Zolfonoun
Journal:  Environ Monit Assess       Date:  2011-07-27       Impact factor: 2.513

3.  UV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma.

Authors:  Seyed Karim Hassaninejad-Darzi; Abdolraouf Samadi-Maybodi; Seyed Mohsen Nikou
Journal:  Iran J Pharm Res       Date:  2016       Impact factor: 1.696

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.