Literature DB >> 18969710

A novel ion selective membrane potentiometric sensor for direct determination of Fe(III) in the presence of Fe(II).

Mohammad Hossein Mashhadizadeh1, Iran Sheikh Shoaei, Niaz Monadi.   

Abstract

A new PVC membrane potentiometric sensor that is highly selective to Fe(III) ions was prepared by using 2-[(2-hydroxy-1-propenyl-buta-1,3-dienylimino)-methyl]-4-p-tolylazo-phenol [HPDTP] as a suitable carrier. The electrode exhibits a linear response for iron(III) ions over a wide concentration range (3.5 x 10(-6) to 4.0 x 10(-2)) with a super Nernstian slope of 28.5 (+/-0.5) per decade. The electrode can be used in the pH range from 4.5 to 6.5. The proposed sensor shows fairly a good discriminating ability towards Fe(3+) ion in comparison to some hard and soft metals such as Fe(2+), Cd(2+), Cu(2+), Al(3+) and Ca(2+). It has a response time of <15s and can be used for at least 2 months without any measurable divergence in response characteristics. The electrode was used in the direct determination of Fe(3+) in aqueous samples and as an indicator electrode in potentiometric titration of Fe(III) ions.

Entities:  

Year:  2004        PMID: 18969710     DOI: 10.1016/j.talanta.2004.05.005

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Flow injection spectrofluorimetric determination of iron in industrial effluents based on fluorescence quenching of 1-naphthol-2- sulfonate.

Authors:  Hossam E M Sayour; Taha M A Razek; Karima F Fadel
Journal:  J Fluoresc       Date:  2011-01-20       Impact factor: 2.217

Review 2.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

3.  Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors.

Authors:  Farnoush Faridbod; Mohammad Reza Ganjali; Rassoul Dinarvand; Parviz Norouzi; Siavash Riahi
Journal:  Sensors (Basel)       Date:  2008-03-11       Impact factor: 3.576

4.  Spectrophotometric and Fluorometric Methods for the Determination of Fe(III) Ions in Water and Pharmaceutical Samples.

Authors:  Ahmed Shahat; Nuha Y Elamin; Wesam Abd El-Fattah
Journal:  ACS Omega       Date:  2021-12-29

5.  Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe2+ or Fe3+ Ions.

Authors:  Rimeh Ismail; Ivana Šeděnková; Zulfiya Černochová; Iryna Romanenko; Ognen Pop-Georgievski; Martin Hrubý; Elena Tomšík
Journal:  Biosensors (Basel)       Date:  2022-06-23

6.  A novel sensor for monitoring of iron(III) ions based on porphyrins.

Authors:  Dana Vlascici; Eugenia Fagadar-Cosma; Iuliana Popa; Vlad Chiriac; Mayte Gil-Agusti
Journal:  Sensors (Basel)       Date:  2012-06-13       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.