Literature DB >> 18969648

Creatinine biosensor based on ammonium ion selective electrode and its application in flow-injection analysis.

Anna Radomska1, Ewa Bodenszac, Stanisław Gła B, Robert Koncki.   

Abstract

A new, highly sensitive, fast responding and stable potentiometric biosensor for creatinine determination is developed. The biosensor is based on an ammonium ion-selective electrode. Creatinine deiminase (EC 3.5.4.21) is chemically immobilized on the surface of the polymeric ion-sensitive membrane in the form of monomolecular layer using a simple, one-step carbodiimide covalent attachment method. The resulting enzyme electrodes are useful for measurement under flow injection analysis (FIA) conditions. The biosensors exhibit excellent operational and storage stability. The enzyme electrodes retain over 70% of initial sensitivity after ten weeks of work under FIA conditions. The storage stability at 4 degrees C is longer than half a year without loss of sensitivity. Under optimized conditions near 30 samples per hour can be analyzed and the determination range (0.02-20.0mmoll(-1)) fully covers creatinine concentrations important from clinical and biomedical point of view. The simple biosensor/FIA system has been successfully used for determination of creatinine in urine, serum and posthemodialysate samples.

Entities:  

Year:  2004        PMID: 18969648     DOI: 10.1016/j.talanta.2004.03.033

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Application of electrochemical biosensors in clinical diagnosis.

Authors:  Rastislav Monošík; Miroslav Stred'anský; Ernest Šturdík
Journal:  J Clin Lab Anal       Date:  2012-01       Impact factor: 2.352

2.  A novel potentiometric sensor for determination of neurotoxin β-N-oxalyl-L-α, β-diaminopropionic acid.

Authors:  Omer Isildak; Furkan Saymaz; Ahmet Karadag; Nesrin Okumus Korkmaz; Azade Attar
Journal:  Biomed Res Int       Date:  2014-05-20       Impact factor: 3.411

3.  Simple and fast method for fabrication of endoscopic implantable sensor arrays.

Authors:  I Bogachan Tahirbegi; Margarita Alvira; Mònica Mir; Josep Samitier
Journal:  Sensors (Basel)       Date:  2014-06-26       Impact factor: 3.576

4.  Development of Ratiometric Fluorescent Biosensors for the Determination of Creatine and Creatinine in Urine.

Authors:  Hong Dinh Duong; Jong Il Rhee
Journal:  Sensors (Basel)       Date:  2017-11-08       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.