| Literature DB >> 18969626 |
M Garcia-Esteban1, D Ansorena, I Astiasarán, J Ruiz.
Abstract
Extraction of dry cured ham volatile compounds by solid-phase microextraction (SPME) was optimized. Different fiber coatings (carboxen/polydimethylsiloxane (CAR/PDMS), divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS), polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB)), times of extraction (15, 30, 60min) and sample preparation (ground samples and homogenates with NaCl saturated solution) were assayed. CAR/PDMS and DVB/CAR/PDMS fiber coatings extracted more than 100 volatile compounds and showed the highest area counts for most volatile compounds. CAR/PDMS coating extracted better those compounds whose Kovats index (KI) was lower than 980 (on average) and DVB/CAR/PDMS those with higher KI. Fifteen minutes of extraction provided a volatile compound profile with lower area counts for most compounds and qualitatively different to that obtained with 30 and 60min of extraction. Homogenates gave a different profile compared to ground samples, with lower total counts for most compounds but higher proportion of aldehydes, and presence of several compounds not found in ground samples.Entities:
Year: 2004 PMID: 18969626 DOI: 10.1016/j.talanta.2004.03.007