Interpretation of CALUX results in view of the EU maximal TEQ level in milk.

Ilse Van Overmeire1, Joris Van Loco, Peter Roos, Sophie Carbonnelle, Leo Goeyens.   

Abstract

Analyses of dioxins in food have become increasingly important since the European Commission has enforced maximal toxic equivalent concentration (TEQ) levels in various food and feed products. Screening methodologies are usually used to exempt those samples that are below the maximum permitted limit and that can, therefore, be released to the market. In addition, one needs to select those samples that require confirmation of their dioxin TEQ level. When bioassays are used as screening tools, the interpretation of the obtained results should consider the higher variability and uncertainty associated with them. This paper explores the use of CALUX data as quantitative screening results. The validation of the method for the polychlorinated dibenzo-p-dioxins (PCDD)/F TEQ determination in milk samples is described with emphasis on the decision limit (CC(alpha)) and the precision of the method. The decision limit amounts to 4.53pg TEQ/g fat. Repeatability and within-lab reproducibility coefficients of variation are below 30%. The newly introduced parameter CC(alpha)(*) of 1.47pg TEQ/g fat delimits with CC(alpha) a range of suspicious results. These data are not significantly different from the maximum limit of 3pg TEQ/g fat and should be confirmed by a confirmatory analytical method such as HRGC-HRMS.

Entities:  

Year:  2004        PMID: 18969553     DOI: 10.1016/j.talanta.2004.05.034

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  Advances in analytical techniques for polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like PCBs.

Authors:  Eric J Reiner; Ray E Clement; Allan B Okey; Chris H Marvin
Journal:  Anal Bioanal Chem       Date:  2006-06-23       Impact factor: 4.142

2.  Time-integrated monitoring of dioxin-like polychlorinated biphenyls (dl-PCBs) in aquatic environments using the ceramic toximeter and the CALUX bioassay.

Authors:  Amr Addeck; Kim Croes; Kersten Van Langenhove; Michael S Denison; Ahmed S Afify; Yue Gao; Marc Elskens; Willy Baeyens
Journal:  Talanta       Date:  2013-12-16       Impact factor: 6.057

3.  Determination of PCDD/Fs, PBDD/Fs and dioxin-like PCBs in human milk from mothers residing in the rural areas in Flanders, using the CALUX bioassay and GC-HRMS.

Authors:  K Croes; A Colles; G Koppen; S De Galan; T Vandermarken; E Govarts; L Bruckers; V Nelen; G Schoeters; N Van Larebeke; M S Denison; M Mampaey; W Baeyens
Journal:  Talanta       Date:  2013-04-06       Impact factor: 6.057

  3 in total