Literature DB >> 18969405

Ion-transport and diffusion coefficients of non-plasticised methacrylic-acrylic ion-selective membranes.

Lee Yook Heng1, Klara Toth, Elizabeth A H Hall.   

Abstract

The ion-transport behaviour of methacrylic-acrylic-based polymers for ion-selective electrode (ISE) membranes was investigated by a spectrophotometric method to determine the apparent diffusion coefficient. By observing the degree of deprotonation of the chromoionophore or chromogenic ionophore, the extent of penetration of cations into the polymer films was determined. The transport of the cations into the optode films depended on the stoichiometry of complexation by the ionophores. The apparent diffusion coefficients, estimated from the deprotonation data were of the order of 10(-12) to 10(-11)cm(2)s(-1). These values indicate that the apparent ion mobility in the methacrylic-acrylic ISE membranes is approximately a thousand times lower than that in plasticised PVC ISE membranes. For some ionophores, the value of the apparent diffusion coefficient could be modulated according to the ionophore content in the membrane and the data obtained for a calixarene containing membrane were tested against a model for facilitated diffusion with chained carriers. The data did not fit a model where intramolecular diffusion was limiting, but were consistent with a first-order rate-limiting mechanism involving an intermediate 1:2 complex between ion and ionophore. In this instance, the lowest values for D(app) were thus not necessarily obtained for lowest ionophore loading and in the range examined, a trend of decreasing D(app) with increasing ionophore was noted.

Entities:  

Year:  2004        PMID: 18969405     DOI: 10.1016/j.talanta.2003.12.051

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  14 in total

Review 1.  The new wave of ion-selective.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2002-08-01       Impact factor: 6.986

2.  Computer Simulation of Ion-Selective Membrane Electrodes and Related Systems by Finite-Element Procedures.

Authors:  W E Morf; E Pretsch; N F De Rooij
Journal:  J Electroanal Chem (Lausanne)       Date:  2007-04-01       Impact factor: 4.464

3.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes.

Authors:  Zsófia Szigeti; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Electroanalysis       Date:  2006-07-01       Impact factor: 3.223

4.  Improving the response behavior of Cd-selective polymeric membrane electrodes by incorporated lipophilic particles.

Authors:  Reto Thürer; Tamás Vigassy; Martina Hirayama; Ernö Pretsch
Journal:  Chem Analityczna       Date:  2006

5.  Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level.

Authors:  Nastassia Rubinova; Karin Chumbimuni-Torres; Eric Bakker
Journal:  Sens Actuators B Chem       Date:  2006-11-16       Impact factor: 7.460

Review 6.  Electrochemical sensors.

Authors:  Eric Bakker; Yu Qin
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

7.  Potentiometric sensors for trace-level analysis.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Trends Analyt Chem       Date:  2005-03       Impact factor: 12.296

Review 8.  Modern potentiometry.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Angew Chem Int Ed Engl       Date:  2007       Impact factor: 15.336

9.  Solid contact potentiometric sensors for trace level measurements.

Authors:  Karin Y Chumbimuni-Torres; Nastassia Rubinova; Aleksandar Radu; Lauro T Kubota; Eric Bakker
Journal:  Anal Chem       Date:  2006-02-15       Impact factor: 6.986

10.  Elimination of undesirable water layers in solid-contact polymeric ion-selective electrodes.

Authors:  Jean-Pierre Veder; Roland De Marco; Graeme Clarke; Ryan Chester; Andrew Nelson; Kathryn Prince; Ernö Pretsch; Eric Bakker
Journal:  Anal Chem       Date:  2008-08-01       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.